Re: 2.4.18: many IDE errors

From: Andre Hedrick (andre@linux-ide.org)
Date: Sun Mar 24 2002 - 03:21:52 EST


It is not a case of bad cables but maybe cable routing.
Also, four 160GB disks eat power!

I have a box dual athlon similar setup w/ 460W ps
I have to wait for the PS to warm up or there is not enough juice to
properly spin up the last drive. However if I replace the four 160GB's
with four 20GB Seagate's no problem.

You are going to need at least a 400W PS w/ almost no ripple to make it
work. If you have this then check the cable routing.

Also hdparm -i /dev/hdX to see if their transfer rates are reduced.

Cheers,

Andre Hedrick
LAD Storage Consulting Group

On Sun, 24 Mar 2002, Eyal Lebedinsky wrote:

> I have six disks in the machine, each a master on the cable. Two are
> on the on-board controller and Four are on two PCI ATA-100 cards.
>
> I am getting disk error (BadCRC) on all disks, intermittently.
>
> I upgraded from RH 2.4.9 (with SGI xfs) to 2.4.18+xfs. Same problem.
> I then applied the 2.4.18-rc1 IDE patches with no improvement (well,
> the four 160GB disks are now fully visible and not clipped to 28bits
> which is a nice surprise).
>
> I checked the memory, replaced the power supply with a hefty 400W,
> I even used a recent mobo (Gigabyte GA-6VTXE). No beef, practically
> the same rate of errors.
>
> I do not believe all six cables are bad (80w all). This is a UP, and
> I did not enalbe local APIC. Should I?
>
> Any ideas where to go from here? On request I have boot messages
> (with errors) and lspci output - I prefer not to overload the list.
>
> The setup is two WD 60GB disks (hda/hdc) which host the root fs (ext2)
> a working area (md2=RAID0, most of the space) and an xfs log
> (md1=RAID1).
>
> hde/g/i/k are Maxtor 160GB, RAID5, xfs (with external log on md0).
>
> I get errors intermittently on all, here is an example after a boot
> following the creation of the raid5 (so a sync was running for about
> two hours).
>
> hda: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hda: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hda: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hda: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hda: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hda: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hda: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hda: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hda: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hda: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hda: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hda: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hda: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hda: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hda: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hda: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hda: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hda: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hda: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hda: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hda: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hda: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hda: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hda: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hda: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hda: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hda: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hda: dma_intr: error=0x84 { DriveStatusError BadCRC }
> ide0: reset: success

Safe transfer rate down grade!

> hdc: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hdc: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hdi: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hdi: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hdi: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hdi: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hdc: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hdc: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hdc: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hdc: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hdc: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hdc: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hdc: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hdc: dma_intr: error=0x84 { DriveStatusError BadCRC }
> ide1: reset: success

Safe transfer rate down grade!

> hdi: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hdi: dma_intr: error=0x84 { DriveStatusError BadCRC }
> hdi: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hdi: dma_intr: error=0x84 { DriveStatusError BadCRC }
> md: md1: sync done.
> raid5: resync finished.
> hdi: dma_intr: status=0x51 { DriveReady SeekComplete Error }
> hdi: dma_intr: error=0x84 { DriveStatusError BadCRC }
> invalidate: busy buffer

GAK!

-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/