Re: Sensors errors with 15-rc6, 15-rc5 was normal

From: Jean Delvare
Date: Wed Dec 21 2005 - 17:03:43 EST


Hi Gene,

Please keep this conversation on the LKML, where it started.

> > Are you getting the temperature value from ACPI, or from a hwmon
> > driver? If the latter, which driver is this, and which hardware
> > monitoring chip do you have?
>
> Its coming from whatever source gkrellm-2.1.28 uses as the default src
> for this, selecting other src's results in -200F or more readings.
> Rebooting back to -rc5, the readings are normal but creeping up, about
> 152F right now.

That's hardly helpful. If gkrellm doesn't tell you where the data comes
from, we just can't use it to debug any issue. Please use "sensors"
instead.

> >From sensors-detect:
> Probing for `Winbond W83627HF'
> Trying address 0x0290... Success!
> (confidence 8, driver `w83781d')
>
> What else?

This is only one part of sensors-detect. I guess it then suggests the
w83627hf driver instead. Which driver are you using, w83627hf or
w83781d?

Please provide:

1* The complete output of sensors-detect.

2* The output of "sensors" in 2.6.15-rc5.

3* The output of "sensors" in 2.6.15-rc6.

4* The diff of your 2.6.15-rc5 kernel config file and 2.6.15-rc6
kernel config file.

Thanks,
--
Jean Delvare
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html