Re: [PATCH] v1 of IBM power meter driver

From: Henrique de Moraes Holschuh
Date: Mon Aug 27 2007 - 21:51:16 EST


On Mon, 27 Aug 2007, Darrick J. Wong wrote:
> documentation doesn't mention any naming conventions for sensors that
> measure Watts, so I am proposing that they be called "powerX_input" in a
> fashion similar to temperature/rpm/current sensors. If that is
> agreeable to everyone, I'll post a follow-up patch to amend the
> documentation.

What unit should we use? Watts are way, way too big as there is no
floating/fixed point in sysfs. 10^-6 W is probably what is called for,
since we already need 10^-3 V and 10^-3 A. Small portable devices can
easily draw less than 10^-3 W nowadays.

--
"One disk to rule them all, One disk to find them. One disk to bring
them all and in the darkness grind them. In the Land of Redmond
where the shadows lie." -- The Silicon Valley Tarot
Henrique Holschuh
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html