[patch 60/74] USB: ftdi_sio: add vendor and product id for Bayer glucose meter serial converter cable

From: Greg KH
Date: Thu Aug 13 2009 - 16:03:53 EST


2.6.30-stable review patch. If anyone has any objections, please let us know.

------------------

From: Marko Hänninen <bugitus@xxxxxxxxx>

commit c47aacc67a3d26dfab9c9b8965975ed2b2010b30 upstream.

Attached patch adds USB vendor and product IDs for Bayer's USB to serial
converter cable used by Bayer blood glucose meters. It seems to be a
FT232RL based device and works without any problem with ftdi_sio driver
when this patch is applied. See: http://winglucofacts.com/cables/


Signed-off-by: Marko Hänninen <bugitus@xxxxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxx>

---
drivers/usb/serial/ftdi_sio.c | 1 +
drivers/usb/serial/ftdi_sio.h | 7 +++++++
2 files changed, 8 insertions(+)

--- a/drivers/usb/serial/ftdi_sio.c
+++ b/drivers/usb/serial/ftdi_sio.c
@@ -672,6 +672,7 @@ static struct usb_device_id id_table_com
{ USB_DEVICE(JETI_VID, JETI_SPC1201_PID) },
{ USB_DEVICE(MARVELL_VID, MARVELL_SHEEVAPLUG_PID),
.driver_info = (kernel_ulong_t)&ftdi_jtag_quirk },
+ { USB_DEVICE(BAYER_VID, BAYER_CONTOUR_CABLE_PID) },
{ }, /* Optional parameter entry */
{ } /* Terminating entry */
};
--- a/drivers/usb/serial/ftdi_sio.h
+++ b/drivers/usb/serial/ftdi_sio.h
@@ -926,6 +926,13 @@
#define MARVELL_SHEEVAPLUG_PID 0x9e8f

/*
+ * Bayer Ascensia Contour blood glucose meter USB-converter cable.
+ * http://winglucofacts.com/cables/
+ */
+#define BAYER_VID 0x1A79
+#define BAYER_CONTOUR_CABLE_PID 0x6001
+
+/*
* BmRequestType: 1100 0000b
* bRequest: FTDI_E2_READ
* wValue: 0


--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html