Re: [patch] ext2/3: document conditions when reliable operation ispossible

From: Ric Wheeler
Date: Thu Aug 27 2009 - 09:10:31 EST


On 08/27/2009 08:24 AM, Theodore Tso wrote:
On Thu, Aug 27, 2009 at 12:19:02AM -0500, Rob Landley wrote:
To me, this isn't a particularly interesting or newsworthy point,
since a competent system administrator

I'm a bit concerned by the argument that we don't need to document
serious pitfalls because every Linux system has a sufficiently
competent administrator they already know stuff that didn't even
come up until the second or third day it was discussed on lkml.

I'm not convinced that information which needs to be known by System
Administrators is best documented in the kernel Documentation
directory. Should there be a HOWTO document on stuff like that?
Sure, if someone wants to put something like that together, having
free documentation about ways to set up your storage stack in a sane
way is not a bad thing.

It should be noted that these sorts of issues are discussed in various
books targetted at System Administrators, and in Usenix's System
Administration tutorials. The computer industry is highly
specialized, and so just because an OS kernel hacker might not be
familiar with these issues, doesn't mean that professionals whose job
it is to run data centers don't know about these things! Similarly,
you could be a whiz at Linux's networking stack, but you might not
know about certain pitfalls in configuring a Cisco router using IOS;
does that mean we should have an IOS tutorial in the kernel
documentation directory? I'm not so sure about that!

"You're documenting it wrong" != "you shouldn't document it".

Sure, but the fact that we don't currently say much about storage
stacks doesn't mean we should accept a patch that might actively
mislead people. I'm NACK'ing the patch on that basis.

who cares about his data and/or
his hardware will (a) have a UPS,

I worked at a company that retested their UPSes a year after
installing them and found that _none_ of them supplied more than 15
seconds charge, and when they dismantled them the batteries had
physically bloated inside their little plastic cases. (Same company
as the dead air conditioner, possibly overheating was involved but
the little _lights_ said everything was ok.)

That was by no means the first UPS I'd seen die, the suckers have a
higher failure rate than hard drives in my experience. This is a
device where the batteries get constantly charged and almost never
tested because if it _does_ fail you just rebooted your production
server, so a lot of smaller companies think they have one but
actually don't.

Sounds like they were using really cheap UPS's; certainly not the kind
I would expect to find in a data center. And if company's system
administrator is using the cheapest possible consumer-grade UPS's,
then yes, they might have a problem. Even an educational institution
like MIT, where I was an network administrator some 15 years ago, had
proper UPS's, *and* we had a diesel generator which kicked in after 15
seconds --- and we tested the diesel generator every Friday morning,
to make sure it worked properly.

, and (b) be running with a hot spare
and/or will imediately replace a failed drive in a RAID array.

Here's hoping they shut the system down properly to install the new
drive in the raid then, eh? Not accidentally pull the plug before
it's finished running the ~7 minutes of shutdown scripts in the last
Red Hat Enterprise I messed with...

Even my home RAID array uses hot-plug SATA disks, so I can replace a
failed disk without shutting down my system. (And yes, I have a
backup battery for the hardware RAID, and the firmware runs periodic
tests on it; the hardware RAID card also will send me e-mail if a RAID
array drive fails and it needs to use my hot-spare. At that point, I
order a new hard drive, secure in the knowledge that the system can
still suffer another drive failure before falling into degraded mode.
And no, this isn't some expensive enterprise RAID setup; this is just
a mid-range Areca RAID card.)

If "degraded array" just means "don't have a replacement disk yet",
then it sounds like what Pavel wants to document is "don't write to
a degraded array at all, because power failures can cost you data
due to write granularity being larger than filesystem block size".
(Which still comes as news to some of us, and you need a way to
remount mount the degraded array read only until the sysadmin can
fix it.)

If you want to document that as a property of RAID arrays, sure. But
it's not something that should live in Documentation/filesystems/ext2.txt
and Documentation/filesystems/ext3.txt. The MD RAID howto might be a
better place, since it's far more likely more users will read it. How
many system administrators read what's in the kernel's Documentation
directory, after all, and this is basic information about how RAID
works; it's not necessarily something that someone would *expect* to
be in kernel documentation, nor would necessarily go looking for it
there. And the reality is that it's not like most people go reading
Documentation/* for pleasure. :-)

BTW, the RAID write atomicity issue and the possibility of failures
cause data loss *is* documented in the Wikipedia article on RAID.
It's not as written as direct practical advice to a system
administrator (you'd have to go to a book that is really targetted at
system administrators to find that sort of thing).

- Ted

One thing that does need fixing for some MD configurations is to stress again that we need to make sure that barrier operations are properly supported or users will need to disable the write cache on devices with volatile write caches.

Ric

--