Re: [PATCH] regulator: Call into regulator driver only whenvoltage min/max really changes.

From: Mark Brown
Date: Sun Dec 12 2010 - 07:18:59 EST


On Sun, Dec 12, 2010 at 02:55:40AM -0800, Saravana Kannan wrote:
> Even in cases where the consumer driver calls the regulator core with
> different voltage min/max values, the application of the various
> voltage constraints could result in the min/max voltage values passed
> to the regulator driver to be unchanged since the previous invocation.

Out of interest do we have any examples of consumers that do this
sufficiently often and/or in paths sufficiently performance critical for
it to be an issue? Sounds like there might be room for optimisation in
those consumers.

> Optimize these cases by not calling into the regulator driver and not
> sending incorrect/unnecessary voltage change notifications.

Acked-by: Mark Brown <broonie@xxxxxxxxxxxxxxxxxxxxxxxxxxx>

The down side of doing this is that if the regulator state changes
underneath us we've now got no way of recovering from that situation.
This is something that's only partially supported by the API at the
minute but it's nice to have a story about how drivers can work with
this. I'll send a patch adding an explicit sync API.
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html