[PATCH 6/6] IIO: ABI documetation.

From: Jonathan Cameron
Date: Mon Oct 17 2011 - 09:16:50 EST


Elements lifted from staging documentation,
drivers/staging/iio/Documentation/sysfs-bus-iio

Signed-off-by: Jonathan Cameron <jic23@xxxxxxxxx>
---
Documentation/ABI/testing/sysfs-bus-iio | 223 +++++++++++++++++++++++++++++++
1 files changed, 223 insertions(+), 0 deletions(-)

diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio
new file mode 100644
index 0000000..965c7cf
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-iio
@@ -0,0 +1,223 @@
+What: /sys/bus/iio/devices/iio:deviceX
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Hardware chip or device accessed by one communication port.
+ Corresponds to a grouping of sensor channels. X is the IIO
+ index of the device.
+
+What: /sys/bus/iio/devices/iio:deviceX/name
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Description of the physical chip / device for device X.
+ Typically a part number.
+
+What: /sys/bus/iio/devices/iio:deviceX/sampling_frequency
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Some devices have internal clocks. This parameter sets the
+ resulting sampling frequency.
+
+What: /sys/bus/iio/devices/iio:deviceX/sampling_frequency_available
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ When the internal sampling clock can only take a small
+ discrete set of values, this file lists those available.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_supply_raw
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Raw (unscaled no bias removal etc) voltage measurement from
+ channel Y. In special cases where the channel does not
+ correspond to externally available input one of the named
+ versions may be used. The number must always be specified and
+ unique to allow association with event codes. Units after
+ application of scale and offset are microvolts.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_voltageY-voltageZ_raw
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Raw (unscaled) differential voltage measurement equivalent to
+ channel Y - channel Z where these channel numbers apply to the
+ physically equivalent inputs when non differential readings are
+ separately available. In differential only parts, then all that
+ is required is a consistent labeling. Units after application
+ of scale and offset are microvolts.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_temp_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_tempX_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_temp_x_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_temp_y_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_temp_z_raw
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Raw (unscaled no bias removal etc) temperature measurement.
+ It an axis is specified it generally means that the temperature
+ sensor is associated with one part of a compound device (e.g.
+ a gyroscope axis). Units after application of scale and offset
+ are milli degrees Celsuis.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_x_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_y_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_z_raw
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Acceleration in direction x, y or z (may be arbitrarily assigned
+ but should match other such assignments on device).
+ Has all of the equivalent parameters as per voltageY. Units
+ after application of scale and offset are m/s^2.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_anglvel_x_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_anglvel_y_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_anglvel_z_raw
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Angular velocity about axis x, y or z (may be arbitrarily
+ assigned) Data converted by application of offset then scale to
+ radians per second. Has all the equivalent parameters as
+ per voltageY. Units after application of scale and offset are
+ radians per second.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_incli_x_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_incli_y_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_incli_z_raw
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Inclination raw reading about axis x, y or z (may be
+ arbitrarily assigned). Data converted by application of offset
+ and scale to Degrees.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_magn_x_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_magn_y_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_magn_z_raw
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Magnetic field along axis x, y or z (may be arbitrarily
+ assigned). Data converted by application of offset
+ then scale to Gauss.
+
+What: /sys/bus/iio/devices/device[n]/illuminance0_input
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ This should return the calculated lux from the light sensor.
+ Units are lumens.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_intensityY_infrared_input
+KernelVersion: 2.6.37
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ This property is supported by sensors that have an infrared
+ sensitive element. Unfortunately this reading is very
+ frequency range dependent and hence tends not to have well
+ defined units.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_intensityY_both_input
+KernelVersion: 2.6.37
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ This property is supported by sensors that have an infrared
+ and visible light sensing element. The visible portion is
+ usually extracted by subtracting the value from a separate
+ infrared only sensor. Unfortunately this reading is very
+ frequency range dependent and hence tends not to have well
+ defined units.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_offset
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_x_offset
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_y_offset
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_z_offset
+What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_offset
+What: /sys/bus/iio/devices/iio:deviceX/in_voltage_offset
+What: /sys/bus/iio/devices/iio:deviceX/in_tempY_offset
+What: /sys/bus/iio/devices/iio:deviceX/in_temp_offset
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ If known for a device, offset to be added to <type>[Y]_raw prior
+ to scaling by <type>[Y]_scale in order to obtain value in the
+ <type> units as specified in <type>[y]_raw documentation.
+ Not present if the offset is always 0 or unknown. If Y or
+ axis <x|y|z> is not present, then the offset applies to all
+ in channels of <type>.
+ May be writable if a variable offset can be applied on the
+ device. Note that this is different to calibbias which
+ is for devices (or drivers) that apply offsets to compensate
+ for variation between different instances of the part, typically
+ adjusted by using some hardware supported calibration procedure.
+ Calibbias is applied internally, offset is applied in userspace
+ to the _raw output.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_scale
+What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_supply_scale
+What: /sys/bus/iio/devices/iio:deviceX/in_voltage_scale
+What: /sys/bus/iio/devices/iio:deviceX/out_voltageY_scale
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_scale
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_peak_scale
+What: /sys/bus/iio/devices/iio:deviceX/in_anglvel_scale
+What: /sys/bus/iio/devices/iio:deviceX/in_magn_scale
+What: /sys/bus/iio/devices/iio:deviceX/in_magn_x_scale
+What: /sys/bus/iio/devices/iio:deviceX/in_magn_y_scale
+What: /sys/bus/iio/devices/iio:deviceX/in_magn_z_scale
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ If known for a device, scale to be applied to <type>Y[_name]_raw
+ post addition of <type>[Y][_name]_offset in order to obtain the
+ measured value in <type> units as specified in
+ <type>[Y][_name]_raw documentation.. If shared across all in
+ channels then Y and <x|y|z> are not present and the value is
+ called <type>[Y][_name]_scale. The peak modifier means this
+ value is applied to <type>Y[_name]_peak_raw values.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_scale_available
+What: /sys/.../iio:deviceX/in_voltageX_scale_available
+What: /sys/.../iio:deviceX/in_voltage-voltage_scale_available
+What: /sys/.../iio:deviceX/out_voltageX_scale_available
+What: /sys/.../iio:deviceX/in_capacitance_scale_available
+KernelVersion: 2.635
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ If a discrete set of scale values are available, they
+ are listed in this attribute.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_x_calibbias
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_y_calibbias
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_z_calibbias
+What: /sys/bus/iio/devices/iio:deviceX/in_anglvel_x_calibbias
+What: /sys/bus/iio/devices/iio:deviceX/in_anglvel_y_calibbias
+What: /sys/bus/iio/devices/iio:deviceX/in_anglvel_z_calibbias
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Hardware applied calibration offset. (assumed to fix production
+ inaccuracies).
+
+What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_calibscale
+What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_supply_calibscale
+What: /sys/bus/iio/devices/iio:deviceX/in_voltage_calibscale
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_x_calibscale
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_y_calibscale
+What: /sys/bus/iio/devices/iio:deviceX/in_accel_z_calibscale
+What: /sys/bus/iio/devices/iio:deviceX/in_anglvel_x_calibscale
+What: /sys/bus/iio/devices/iio:deviceX/in_anglvel_y_calibscale
+What: /sys/bus/iio/devices/iio:deviceX/in_anglvel_z_calibscale
+What: /sys/.../iio:deviceX/in_intensityY_infrared_calibscale
+What: /sys/.../iio:deviceX/in_intensityY_both_calibscale
+KernelVersion: 2.6.35
+Contact: linux-iio@xxxxxxxxxxxxxxx
+Description:
+ Hardware applied calibration scale factor. (assumed to fix
+ production inaccuracies). If shared across all channels,
+ <type>_calibscale is used.