[PATCH v3 2/2] power: Charger-Manager: add properties forpower-supply-class

From: Donggeun Kim
Date: Tue Dec 27 2011 - 04:48:03 EST


Charger Manager provides power-supply-class aggregating
information from multiple chargers and a fuel-gauge.

Signed-off-by: Donggeun Kim <dg77.kim@xxxxxxxxxxx>
Signed-off-by: MyungJoo Ham <myungjoo.ham@xxxxxxxxxxx>
Signed-off-by: Kyungmin Park <kyungmin.park@xxxxxxxxxxx>
---
Documentation/power/charger-manager.txt | 14 ++
drivers/power/charger-manager.c | 295 ++++++++++++++++++++++++++++++-
include/linux/power/charger-manager.h | 17 ++
3 files changed, 325 insertions(+), 1 deletions(-)

diff --git a/Documentation/power/charger-manager.txt b/Documentation/power/charger-manager.txt
index 10edc36..55f2170 100644
--- a/Documentation/power/charger-manager.txt
+++ b/Documentation/power/charger-manager.txt
@@ -98,6 +98,11 @@ battery), an instance of Charger Manager is attached to it.

struct charger_desc {

+char *psy_name;
+ : The power-supply-class name of the battery. Default is
+ "battery" if psy_name is NULL. Users can access the psy entries
+ at "/sys/class/power_supply/[psy_name]/".
+
enum polling_modes polling_mode;
: CM_POLL_DISABLE: do not poll this battery.
CM_POLL_ALWAYS: always poll this battery.
@@ -106,6 +111,12 @@ enum polling_modes polling_mode;
CM_POLL_CHARGING_ONLY: poll this battery if and only if the
battery is being charged.

+unsigned int fullbatt_uV;
+ : If specified with a non-zero value, Charger Manager assumes
+ that the battery is full (capacity = 100) if the battery is not being
+ charged and the battery voltage is equal to or greater than
+ fullbatt_uV.
+
unsigned int polling_interval_ms;
: Required polling interval in ms. Charger Manager will poll
this battery every polling_interval_ms or more frequently.
@@ -131,10 +142,13 @@ char *psy_fuel_gauge;
: Power-supply-class name of the fuel gauge.

int (*temperature_out_of_range)(int *mC);
+bool measure_battery_temp;
: This callback returns 0 if the temperature is safe for charging,
a positive number if it is too hot to charge, and a negative number
if it is too cold to charge. With the variable mC, the callback returns
the temperature in 1/1000 of centigrade.
+ The source of temperature can be battery or ambient one according to
+ the value of measure_battery_temp.
};

5. Other Considerations
diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c
index c90cefc..b1beef1 100644
--- a/drivers/power/charger-manager.c
+++ b/drivers/power/charger-manager.c
@@ -123,6 +123,32 @@ static bool is_ext_pwr_online(struct charger_manager *cm)
}

/**
+ * get_batt_uV - Get the voltage level of the battery
+ * @cm: the Charger Manager representing the battery.
+ * @uV: the voltage level returned.
+ *
+ * Returns 0 if there is no error.
+ * Returns a negative value on error.
+ */
+static int get_batt_uV(struct charger_manager *cm, int *uV)
+{
+ union power_supply_propval val;
+ int ret;
+
+ if (cm->fuel_gauge)
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_VOLTAGE_NOW, &val);
+ else
+ return -ENODEV;
+
+ if (ret)
+ return ret;
+
+ *uV = val.intval;
+ return 0;
+}
+
+/**
* is_charging - Returns true if the battery is being charged.
* @cm: the Charger Manager representing the battery.
*/
@@ -370,6 +396,208 @@ static bool cm_monitor(void)
return stop;
}

+static int charger_get_property(struct power_supply *psy,
+ enum power_supply_property psp,
+ union power_supply_propval *val)
+{
+ struct charger_manager *cm = container_of(psy,
+ struct charger_manager, charger_psy);
+ struct charger_desc *desc = cm->desc;
+ int i, ret = 0, uV;
+
+ switch (psp) {
+ case POWER_SUPPLY_PROP_STATUS:
+ if (is_charging(cm))
+ val->intval = POWER_SUPPLY_STATUS_CHARGING;
+ else if (is_ext_pwr_online(cm))
+ val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
+ else
+ val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
+ break;
+ case POWER_SUPPLY_PROP_HEALTH:
+ if (cm->emergency_stop > 0)
+ val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
+ else if (cm->emergency_stop < 0)
+ val->intval = POWER_SUPPLY_HEALTH_COLD;
+ else
+ val->intval = POWER_SUPPLY_HEALTH_GOOD;
+ break;
+ case POWER_SUPPLY_PROP_PRESENT:
+ if (is_batt_present(cm))
+ val->intval = 1;
+ else
+ val->intval = 0;
+ break;
+ case POWER_SUPPLY_PROP_VOLTAGE_NOW:
+ ret = get_batt_uV(cm, &i);
+ val->intval = i;
+ break;
+ case POWER_SUPPLY_PROP_CURRENT_NOW:
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_CURRENT_NOW, val);
+ break;
+ case POWER_SUPPLY_PROP_TEMP:
+ /* in thenth of centigrade */
+ if (cm->last_temp_mC == INT_MIN)
+ desc->temperature_out_of_range(&cm->last_temp_mC);
+ val->intval = cm->last_temp_mC / 100;
+ if (!desc->measure_battery_temp)
+ ret = -ENODEV;
+ break;
+ case POWER_SUPPLY_PROP_TEMP_AMBIENT:
+ /* in thenth of centigrade */
+ if (cm->last_temp_mC == INT_MIN)
+ desc->temperature_out_of_range(&cm->last_temp_mC);
+ val->intval = cm->last_temp_mC / 100;
+ if (desc->measure_battery_temp)
+ ret = -ENODEV;
+ break;
+ case POWER_SUPPLY_PROP_CAPACITY:
+ if (!cm->fuel_gauge) {
+ ret = -ENODEV;
+ break;
+ }
+
+ if (!is_batt_present(cm)) {
+ /* There is no battery. Assume 100% */
+ val->intval = 100;
+ break;
+ }
+
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_CAPACITY, val);
+ if (ret)
+ break;
+
+ if (val->intval > 100) {
+ val->intval = 100;
+ break;
+ }
+ if (val->intval < 0)
+ val->intval = 0;
+
+ /* Do not adjust SOC when charging: voltage is overrated */
+ if (is_charging(cm))
+ break;
+
+ /*
+ * If the capacity value is inconsistent, calibrate it base on
+ * the battery voltage values and the thresholds given as desc
+ */
+ ret = get_batt_uV(cm, &uV);
+ if (ret) {
+ /* Voltage information not available. No calibration */
+ ret = 0;
+ break;
+ }
+
+ if (desc->fullbatt_uV > 0 && uV >= desc->fullbatt_uV &&
+ !is_charging(cm)) {
+ val->intval = 100;
+ break;
+ }
+
+ break;
+ case POWER_SUPPLY_PROP_ONLINE:
+ if (is_ext_pwr_online(cm))
+ val->intval = 1;
+ else
+ val->intval = 0;
+ break;
+ case POWER_SUPPLY_PROP_CHARGE_FULL:
+ if (cm->fuel_gauge) {
+ if (cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_CHARGE_FULL, val) == 0)
+ break;
+ }
+
+ if (is_ext_pwr_online(cm)) {
+ /* Not full if it's charging. */
+ if (is_charging(cm)) {
+ val->intval = 0;
+ break;
+ }
+ /*
+ * Full if it's powered but not charging andi
+ * not forced stop by emergency
+ */
+ if (!cm->emergency_stop) {
+ val->intval = 1;
+ break;
+ }
+ }
+
+ /* Full if it's over the fullbatt voltage */
+ ret = get_batt_uV(cm, &uV);
+ if (!ret && desc->fullbatt_uV > 0 && uV >= desc->fullbatt_uV &&
+ !is_charging(cm)) {
+ val->intval = 1;
+ break;
+ }
+
+ /* Full if the cap is 100 */
+ if (cm->fuel_gauge) {
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_CAPACITY, val);
+ if (!ret && val->intval >= 100 && !is_charging(cm)) {
+ val->intval = 1;
+ break;
+ }
+ }
+
+ val->intval = 0;
+ ret = 0;
+ break;
+ case POWER_SUPPLY_PROP_CHARGE_NOW:
+ if (is_charging(cm)) {
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_CHARGE_NOW,
+ val);
+ if (ret) {
+ val->intval = 1;
+ ret = 0;
+ } else {
+ /* If CHARGE_NOW is supplied, use it */
+ val->intval = (val->intval > 0) ?
+ val->intval : 1;
+ }
+ } else {
+ val->intval = 0;
+ }
+ break;
+ default:
+ return -EINVAL;
+ }
+ return ret;
+}
+
+#define NUM_CHARGER_PSY_OPTIONAL (4)
+static enum power_supply_property default_charger_props[] = {
+ /* Guaranteed to provide */
+ POWER_SUPPLY_PROP_STATUS,
+ POWER_SUPPLY_PROP_HEALTH,
+ POWER_SUPPLY_PROP_PRESENT,
+ POWER_SUPPLY_PROP_VOLTAGE_NOW,
+ POWER_SUPPLY_PROP_CAPACITY,
+ POWER_SUPPLY_PROP_ONLINE,
+ POWER_SUPPLY_PROP_CHARGE_FULL,
+ /*
+ * Optional properties are:
+ * POWER_SUPPLY_PROP_CHARGE_NOW,
+ * POWER_SUPPLY_PROP_CURRENT_NOW,
+ * POWER_SUPPLY_PROP_TEMP, and
+ * POWER_SUPPLY_PROP_TEMP_AMBIENT,
+ */
+};
+
+static struct power_supply psy_default = {
+ .name = "battery",
+ .type = POWER_SUPPLY_TYPE_BATTERY,
+ .properties = default_charger_props,
+ .num_properties = ARRAY_SIZE(default_charger_props),
+ .get_property = charger_get_property,
+};
+
/**
* cm_setup_timer - For in-suspend monitoring setup wakeup alarm
* for suspend_again.
@@ -533,6 +761,7 @@ static int charger_manager_probe(struct platform_device *pdev)
struct charger_desc *desc = dev_get_platdata(&pdev->dev);
struct charger_manager *cm;
int ret = 0, i = 0;
+ union power_supply_propval val;

if (g_desc && !rtc_dev && g_desc->rtc_name) {
rtc_dev = rtc_class_open(g_desc->rtc_name);
@@ -627,11 +856,68 @@ static int charger_manager_probe(struct platform_device *pdev)

platform_set_drvdata(pdev, cm);

+ memcpy(&cm->charger_psy, &psy_default,
+ sizeof(psy_default));
+ if (!desc->psy_name) {
+ strncpy(cm->psy_name_buf, psy_default.name,
+ PSY_NAME_MAX);
+ } else {
+ strncpy(cm->psy_name_buf, desc->psy_name, PSY_NAME_MAX);
+ }
+ cm->charger_psy.name = cm->psy_name_buf;
+
+ /* Allocate for psy properties because they may vary */
+ cm->charger_psy.properties = kzalloc(sizeof(enum power_supply_property)
+ * (ARRAY_SIZE(default_charger_props) +
+ NUM_CHARGER_PSY_OPTIONAL),
+ GFP_KERNEL);
+ if (!cm->charger_psy.properties) {
+ dev_err(&pdev->dev, "Cannot allocate for psy properties.\n");
+ ret = -ENOMEM;
+ goto err_chg_stat;
+ }
+ memcpy(cm->charger_psy.properties, default_charger_props,
+ sizeof(enum power_supply_property) *
+ ARRAY_SIZE(default_charger_props));
+ cm->charger_psy.num_properties = psy_default.num_properties;
+
+ /* Find which optional psy-properties are available */
+ if (!cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_CHARGE_NOW, &val)) {
+ cm->charger_psy.properties[cm->charger_psy.num_properties] =
+ POWER_SUPPLY_PROP_CHARGE_NOW;
+ cm->charger_psy.num_properties++;
+ }
+ if (!cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_CURRENT_NOW,
+ &val)) {
+ cm->charger_psy.properties[cm->charger_psy.num_properties] =
+ POWER_SUPPLY_PROP_CURRENT_NOW;
+ cm->charger_psy.num_properties++;
+ }
+ if (!desc->measure_battery_temp) {
+ cm->charger_psy.properties[cm->charger_psy.num_properties] =
+ POWER_SUPPLY_PROP_TEMP_AMBIENT;
+ cm->charger_psy.num_properties++;
+ }
+ if (desc->measure_battery_temp) {
+ cm->charger_psy.properties[cm->charger_psy.num_properties] =
+ POWER_SUPPLY_PROP_TEMP;
+ cm->charger_psy.num_properties++;
+ }
+
+ ret = power_supply_register(NULL, &cm->charger_psy);
+ if (ret) {
+ dev_err(&pdev->dev, "Cannot register charger-manager with"
+ " name \"%s\".\n", cm->charger_psy.name);
+ goto err_register;
+ }
+
ret = regulator_bulk_get(&pdev->dev, desc->num_charger_regulators,
desc->charger_regulators);
if (ret) {
dev_err(&pdev->dev, "Cannot get charger regulators.\n");
- goto err_chg_stat;
+ goto err_bulk_get;
}

ret = try_charger_enable(cm, true);
@@ -651,6 +937,10 @@ err_chg_enable:
if (desc->charger_regulators)
regulator_bulk_free(desc->num_charger_regulators,
desc->charger_regulators);
+err_bulk_get:
+ power_supply_unregister(&cm->charger_psy);
+err_register:
+ kfree(cm->charger_psy.properties);
err_chg_stat:
kfree(cm->charger_stat);
err_no_charger_stat:
@@ -675,6 +965,9 @@ static int __devexit charger_manager_remove(struct platform_device *pdev)
if (desc->charger_regulators)
regulator_bulk_free(desc->num_charger_regulators,
desc->charger_regulators);
+
+ power_supply_unregister(&cm->charger_psy);
+ kfree(cm->charger_psy.properties);
kfree(cm->charger_stat);
kfree(cm->desc);
kfree(cm);
diff --git a/include/linux/power/charger-manager.h b/include/linux/power/charger-manager.h
index 1af4c17..c0b7b04 100644
--- a/include/linux/power/charger-manager.h
+++ b/include/linux/power/charger-manager.h
@@ -48,8 +48,12 @@ struct charger_global_desc {

/**
* struct charger_desc
+ * @psy_name: the name of power-supply-class for charger manager
* @polling_mode:
* Determine which polling mode will be used
+ * @fullbatt_uV: voltage in microvolt
+ * If it is not being charged and VBATT >= fullbatt_uV,
+ * it is assumed to be full.
* @polling_interval_ms: interval in millisecond at which
* charger manager will monitor battery health
* @battery_present:
@@ -63,11 +67,18 @@ struct charger_global_desc {
* return_value > 0: overheat
* return_value == 0: normal
* return_value < 0: cold
+ * @measure_battery_temp:
+ * true: measure battery temperature
+ * false: measure ambient temperature
*/
struct charger_desc {
+ char *psy_name;
+
enum polling_modes polling_mode;
unsigned int polling_interval_ms;

+ unsigned int fullbatt_uV;
+
enum data_source battery_present;

char **psy_charger_stat;
@@ -78,6 +89,7 @@ struct charger_desc {
char *psy_fuel_gauge;

int (*temperature_out_of_range)(int *mC);
+ bool measure_battery_temp;
};

#define PSY_NAME_MAX 30
@@ -93,6 +105,8 @@ struct charger_desc {
* @emergency_stop:
* When setting true, stop charging
* @last_temp_mC: the measured temperature in milli-Celsius
+ * @psy_name_buf: the name of power-supply-class for charger manager
+ * @charger_psy: power_supply for charger manager
* @status_save_ext_pwr_inserted:
* saved status of external power before entering suspend-to-RAM
* @status_save_batt:
@@ -111,6 +125,9 @@ struct charger_manager {
int emergency_stop;
int last_temp_mC;

+ char psy_name_buf[PSY_NAME_MAX + 1];
+ struct power_supply charger_psy;
+
bool status_save_ext_pwr_inserted;
bool status_save_batt;
};
--
1.7.4.1

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/