Re: [RFC/RFT][PATCH 1/3] regulator: core: Add enable_pulldown flagto indicate pulldown on EN input

From: Mark Brown
Date: Fri Mar 01 2013 - 04:22:49 EST


On Fri, Feb 15, 2013 at 05:19:21PM +0800, Axel Lin wrote:
> Add enable_pulldown flag to indicate pulldown on EN input when using
> regulator_enable_regmap and friends APIs.

> - return (val & rdev->desc->enable_mask) != 0;
> + if (rdev->desc->enable_pulldown)
> + return (val & rdev->desc->enable_mask) == 0;
> + else
> + return (val & rdev->desc->enable_mask) != 0;

Pulldown isn't the word here... it's saying that enable is inverted,
not that it's pulled down. Pulling something down is more an electrical
engineering thing saying what the default value for a signal is if it's
not otherwise driven, it doesn't really make sense in terms of a
register value.

Something like enable_active_low or enable_invert?