Re: [PATCH V3 1/5] spi: s3c64xx: modified error interrupt handlingand init

From: Mark Brown
Date: Mon Apr 01 2013 - 09:03:17 EST


On Wed, Mar 13, 2013 at 12:13:30PM +0530, Girish K S wrote:
> From: Girish K S <girishks2000@xxxxxxxxx>
>
> The status of the interrupt is available in the status register,
> so reading the clear pending register and writing back the same
> value will not actually clear the pending interrupts. This patch
> modifies the interrupt handler to read the status register and
> clear the corresponding pending bit in the clear pending register.

Applied, thanks.

> Signed-off-by: Girish K S <ks.giri@xxxxxxxxxxx>

This and the committer e-mail address (the From: above) really ought to
match up with each other.

Attachment: signature.asc
Description: Digital signature