Re: [PATCH RESEND] regulator: palmas: Fix off-by-one for ramp_delayand register value mapping

From: Laxman Dewangan
Date: Mon Apr 22 2013 - 08:28:16 EST


On Monday 22 April 2013 03:52 PM, Axel Lin wrote:
Datasheet says:
Time Step (TSTEP) selection, when changing the output voltage, the new value is
reached through successive voltage steps (if not bypassed). The equivalent
programmable slew rate of the output voltage is:

TSTEP[1:0]: 00 Jump (no slope control)
TSTEP[1:0]: 01 10mV/us
TSTEP[1:0]: 10 5mV/us (default)
TSTEP[1:0]: 11 2.5mV/us

Signed-off-by: Axel Lin <axel.lin@xxxxxxxxxx>
---

Acked-by: Laxman Dewangan <ldewangan@xxxxxxxxxx>

--