Re: permission to move definition of struct rpmsg_channel_info

From: Thierry Reding
Date: Tue Sep 10 2013 - 13:01:53 EST


On Mon, Sep 09, 2013 at 10:06:24PM +0200, Ohad Ben-Cohen wrote:
> On Mon, Sep 9, 2013 at 2:57 PM, Thierry Reding <thierry.reding@xxxxxxxxx> wrote:
[...]
> > Looking at the remoteproc core, it seems that there's no direct way to
> > change the firmware running on a remoteproc at runtime.
>
> One way is to unload and load the driver, but you can also use the
> bind/unbind sysfs files of your driver (echo -n device-name >
> /sys/..../{un}bind).

I'm not quite sure how that solves the issue with replacing the firmware
image. The driver will still request the same firmware on rebind, so the
only way to have a different firmware loaded would be to replace the
file. That sounds sub-optimal. But it's not very important at this stage
so it can be deferred until (and if) it becomes a real issue.

> Does that help?

Yes, thanks very much for confirming.

Thierry

Attachment: pgp00000.pgp