Re: [PATCH v2] watchdog: s3c2410_wdt: Handle rounding a little better for timeout

From: Wim Van Sebroeck
Date: Wed Jan 08 2014 - 15:04:09 EST


Hi Doug,

> The existing watchdog timeout worked OK but didn't deal with
> rounding in an ideal way when dividing out all of its clocks.
>
> Specifically if you had a timeout of 32 seconds and an input clock of
> 66666666, you'd end up setting a timeout of 31.9998 seconds and
> reporting a timeout of 31 seconds.
>
> Specifically DBG printouts showed:
> s3c2410wdt_set_heartbeat: count=16666656, timeout=32, freq=520833
> s3c2410wdt_set_heartbeat: timeout=32, divisor=255, count=16666656 (0000ff4f)
> and the final timeout reported to the user was:
> ((count / divisor) * divisor) / freq
> (0xff4f * 255) / 520833 = 31 (truncated from 31.9998)
> the technically "correct" value is:
> (0xff4f * 255) / (66666666.0 / 128) = 31.9998
>
> By using "DIV_ROUND_UP" we can be a little more correct.
> s3c2410wdt_set_heartbeat: count=16666688, timeout=32, freq=520834
> s3c2410wdt_set_heartbeat: timeout=32, divisor=255, count=16666688 (0000ff50)
> and the final timeout reported to the user:
> (0xff50 * 255) / 520834 = 32
> the technically "correct" value is:
> (0xff50 * 255) / (66666666.0 / 128) = 32.0003
>
> We'll use a DIV_ROUND_UP to solve this, generally erroring on the side
> of reporting shorter values to the user and setting the watchdog to
> slightly longer than requested:
> * Round input frequency up to assume watchdog is counting faster.
> * Round divisions by divisor up to give us extra time.
>
> At the same time we can avoid a for loop by just doing the right math.
>
> Signed-off-by: Doug Anderson <dianders@xxxxxxxxxxxx>
> ---
> Changes in v2:
> - Avoid a for loop as per Guenter.

Patch added to linux-watchdog-next.

Kind regards,
Wim.

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html