Re: [PATCH 09/10] watchdog: xilinx: Add missing binding

From: Michal Simek
Date: Mon Feb 03 2014 - 10:14:13 EST


On 02/03/2014 04:06 PM, Arnd Bergmann wrote:
> On Friday 31 January 2014, Michal Simek wrote:
>> +Optional properties:
>> +- clock-frequency : Frequency of clock in Hz
>> +- xlnx,wdt-enable-once : 0 - Watchdog can be restarted
>> + 1 - Watchdog can be enabled just once
>> +- xlnx,wdt-interval : Watchdog timeout interval in 2^<val> clock cycles,
>> + <val> is integer from 8 to 31.
>> +
>
> The latter two don't really seem to be xilinx specific, it would be
> reasonable to have a standard watchdog binding that mandates a common
> format for them.
>
> I'm not sure about the enable-once flag, which seems to just map to the
> "nowayout" watchdog option that is not a hardware feature at all
> and should probably be kept as a software setting only, rather than
> settable through DT. If it is kept, it should have a standard name and
> get turned into a boolean (present/absent) property rather than a
> 0/1 integer property.
>
> The interval should really be specified in terms of seconds or miliseconds,
> not in clock cycles.

Intention wasn't to fix binding but document current one
which is in mainline for a long time.

Apart of this - yes, wdt-enable-once is nowayout and wdt-interval should be timeout
is seconds, and clock-frequency should go out and use CCF for getting clock.

Thanks,
Michal


--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/