[PATCH v2 30/33] thermal: exynos: remove test_mux pdata field

From: Bartlomiej Zolnierkiewicz
Date: Thu Nov 13 2014 - 10:07:23 EST


Replace pdata->test_mux check in get_con_reg() by explicitly
checking for SoC type.

Also since the used pdata->test_mux value is always identical
use it directly and remove pdata->test_mux completely.

There should be no functional changes caused by this patch.

Cc: Amit Daniel Kachhap <amit.daniel@xxxxxxxxxxx>
Cc: Lukasz Majewski <l.majewski@xxxxxxxxxxx>
Cc: Eduardo Valentin <edubezval@xxxxxxxxx>
Cc: Zhang Rui <rui.zhang@xxxxxxxxx>
Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@xxxxxxxxxxx>
Acked-by: Kyungmin Park <kyungmin.park@xxxxxxxxxxx>
---
drivers/thermal/samsung/exynos_tmu.c | 5 +++--
drivers/thermal/samsung/exynos_tmu.h | 2 --
drivers/thermal/samsung/exynos_tmu_data.c | 2 --
3 files changed, 3 insertions(+), 6 deletions(-)

diff --git a/drivers/thermal/samsung/exynos_tmu.c b/drivers/thermal/samsung/exynos_tmu.c
index 65eeecc..2fcb4cd 100644
--- a/drivers/thermal/samsung/exynos_tmu.c
+++ b/drivers/thermal/samsung/exynos_tmu.c
@@ -193,8 +193,9 @@ static u32 get_con_reg(struct exynos_tmu_data *data, u32 con)
{
struct exynos_tmu_platform_data *pdata = data->pdata;

- if (pdata->test_mux)
- con |= (pdata->test_mux << EXYNOS4412_MUX_ADDR_SHIFT);
+ if (data->soc == SOC_ARCH_EXYNOS4412 ||
+ data->soc == SOC_ARCH_EXYNOS3250)
+ con |= (EXYNOS4412_MUX_ADDR_VALUE << EXYNOS4412_MUX_ADDR_SHIFT);

con &= ~(EXYNOS_TMU_REF_VOLTAGE_MASK << EXYNOS_TMU_REF_VOLTAGE_SHIFT);
con |= pdata->reference_voltage << EXYNOS_TMU_REF_VOLTAGE_SHIFT;
diff --git a/drivers/thermal/samsung/exynos_tmu.h b/drivers/thermal/samsung/exynos_tmu.h
index 2eb4cb9..8de0f82 100644
--- a/drivers/thermal/samsung/exynos_tmu.h
+++ b/drivers/thermal/samsung/exynos_tmu.h
@@ -89,7 +89,6 @@ enum soc_type {
* @first_point_trim: temp value of the first point trimming
* @second_point_trim: temp value of the second point trimming
* @default_temp_offset: default temperature offset in case of no trimming
- * @test_mux; information if SoC supports test MUX
* @cal_type: calibration type for temperature
* @freq_clip_table: Table representing frequency reduction percentage.
* @freq_tab_count: Count of the above table as frequency reduction may
@@ -115,7 +114,6 @@ struct exynos_tmu_platform_data {
u8 first_point_trim;
u8 second_point_trim;
u8 default_temp_offset;
- u8 test_mux;

enum calibration_type cal_type;
enum soc_type type;
diff --git a/drivers/thermal/samsung/exynos_tmu_data.c b/drivers/thermal/samsung/exynos_tmu_data.c
index d90b050..708c3e1 100644
--- a/drivers/thermal/samsung/exynos_tmu_data.c
+++ b/drivers/thermal/samsung/exynos_tmu_data.c
@@ -109,7 +109,6 @@ struct exynos_tmu_init_data const exynos3250_default_tmu_data = {
{
EXYNOS3250_TMU_DATA,
.type = SOC_ARCH_EXYNOS3250,
- .test_mux = EXYNOS4412_MUX_ADDR_VALUE,
},
},
.tmu_count = 1,
@@ -160,7 +159,6 @@ struct exynos_tmu_init_data const exynos4412_default_tmu_data = {
{
EXYNOS4412_TMU_DATA,
.type = SOC_ARCH_EXYNOS4412,
- .test_mux = EXYNOS4412_MUX_ADDR_VALUE,
},
},
.tmu_count = 1,
--
1.8.2.3

--