[PATCH v3 14/16] drivers: sh: Disable PM runtime for multi-platform ARM with genpd

From: Geert Uytterhoeven
Date: Wed Jul 01 2015 - 12:01:48 EST


If the default PM Domain using PM_CLK is used for PM runtime, the real
Clock Domain cannot be registered from DT later.

Hence do not enable it when running a multi-platform kernel with genpd
support on R-Car or RZ. The CPG/MSTP Clock Domain driver will take care
of PM runtime management of the module clocks.

Now most multi-platform ARM shmobile platforms (SH-Mobile, R-Mobile,
R-Car, RZ) use DT-based PM Domains to take care of PM runtime management
of the module clocks, simplify the platform logic by replacing the
explicit SoC checks by a single check for the presence of MSTP clocks in
DT.

Backwards-compatiblity with old DTs (mainly for R-Car Gen2) is provided
by checking for the presence of a "#power-domain-cells" property in DT.

The default PM Domain is still needed for:
- backwards-compatibility with old DTs that lack PM Domain properties,
- the CONFIG_PM=n case,
- legacy (non-DT) ARM/shmobile platforms without genpd support
(r8a7778, r8a7779),
- legacy SuperH.

Signed-off-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx>
Reviewed-by: Ulf Hansson <ulf.hansson@xxxxxxxxxx>
---
v3:
- The runtime check must stay for the ARM multiplatform CONFIG_PM=n
case, to prevent the code from running on non-shmobile machines,
- Provide backwards-compatibility with old DTs,
- Extract EMMA Mobile EV2 removal into a separate patch,
- Replace explicit platform checks by a check for the presence of MSTP
clocks,
- Drop references to legacy r8a7740/sh73a0, which are gone,
- Rephrase description,

v2:
- Add Reviewed-by,
- Just stop compiling pm_runtime.c instead of using a runtime check,
as no multi-platform ARM platforms need this anymore.
---
drivers/sh/pm_runtime.c | 18 +++++-------------
1 file changed, 5 insertions(+), 13 deletions(-)

diff --git a/drivers/sh/pm_runtime.c b/drivers/sh/pm_runtime.c
index ad9188138ed56ffb..25abd4eb7d102113 100644
--- a/drivers/sh/pm_runtime.c
+++ b/drivers/sh/pm_runtime.c
@@ -35,19 +35,11 @@ static struct pm_clk_notifier_block platform_bus_notifier = {
static int __init sh_pm_runtime_init(void)
{
if (IS_ENABLED(CONFIG_ARCH_SHMOBILE_MULTI)) {
- if (!of_machine_is_compatible("renesas,r7s72100") &&
-#ifndef CONFIG_PM_GENERIC_DOMAINS_OF
- !of_machine_is_compatible("renesas,r8a73a4") &&
- !of_machine_is_compatible("renesas,r8a7740") &&
- !of_machine_is_compatible("renesas,sh73a0") &&
-#endif
- !of_machine_is_compatible("renesas,r8a7778") &&
- !of_machine_is_compatible("renesas,r8a7779") &&
- !of_machine_is_compatible("renesas,r8a7790") &&
- !of_machine_is_compatible("renesas,r8a7791") &&
- !of_machine_is_compatible("renesas,r8a7792") &&
- !of_machine_is_compatible("renesas,r8a7793") &&
- !of_machine_is_compatible("renesas,r8a7794"))
+ if (!of_find_compatible_node(NULL, NULL,
+ "renesas,cpg-mstp-clocks"))
+ return 0;
+ if (IS_ENABLED(CONFIG_PM_GENERIC_DOMAINS_OF) &&
+ of_find_node_with_property(NULL, "#power-domain-cells"))
return 0;
}

--
1.9.1

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/