[PATCH 3.19.y-ckt 001/128] vf610_adc: Fix internal temperature calculation

From: Kamal Mostafa
Date: Wed Dec 16 2015 - 13:23:32 EST


3.19.8-ckt12 -stable review patch. If anyone has any objections, please let me know.

------------------

From: Bhuvanchandra DV <bhuvanchandra.dv@xxxxxxxxxxx>

commit 6219f432ec037317a77c40910da12a626c34af1c upstream.

Calculate ADCR_VTEMP25 using VTEMP25 at VREFH_ADC 3V3. Existing
calculations consider the typical values provided in datasheet.
Those typical values are valid for VREFH_ADC at 3.0V. VTEMP25
is different for different VREFH_ADC voltages. With VREFH_ADC
at 3.3V, voltage at 25ÂC is 0.699V. Hence update the VTEMP25
to 0.699V which gives ADCR@Temp25 as 867.

Formula for finding ADCR@Temp25:
ADCR@Temp25 = (ADCR@Vdd * V@TEMP25 * 10) / VDDconv

ADCR@Vdd for 12-Bit ADC = 4095
VDDconv = VREFH_ADC * 10

VREFH_ADC@xxxx
ADCR@Temp25 = (4095 * .699 * 10) / 33
ADCR@Temp25 ~= 867

| VREFH_ADC | V@TEMP25 | VDDconv | ADCR@Temp25 |
| 3.0V | 0.696mV | 30 | 950 |
| 3.3V | 0.699mV | 33 | 867 |

Signed-off-by: Bhuvanchandra DV <bhuvanchandra.dv@xxxxxxxxxxx>
Acked-by: Fugang Duan <B38611@xxxxxxxxxxxxx>
Signed-off-by: Jonathan Cameron <jic23@xxxxxxxxxx>
Signed-off-by: Kamal Mostafa <kamal@xxxxxxxxxxxxx>
---
drivers/iio/adc/vf610_adc.c | 19 ++++++++++++++-----
1 file changed, 14 insertions(+), 5 deletions(-)

diff --git a/drivers/iio/adc/vf610_adc.c b/drivers/iio/adc/vf610_adc.c
index 60617ed..cf56404 100644
--- a/drivers/iio/adc/vf610_adc.c
+++ b/drivers/iio/adc/vf610_adc.c
@@ -98,6 +98,13 @@
#define VF610_ADC_CALF 0x2
#define VF610_ADC_TIMEOUT msecs_to_jiffies(100)

+/* V at 25ÂC of 696 mV */
+#define VF610_VTEMP25_3V0 950
+/* V at 25ÂC of 699 mV */
+#define VF610_VTEMP25_3V3 867
+/* Typical sensor slope coefficient at all temperatures */
+#define VF610_TEMP_SLOPE_COEFF 1840
+
enum clk_sel {
VF610_ADCIOC_BUSCLK_SET,
VF610_ADCIOC_ALTCLK_SET,
@@ -513,11 +520,13 @@ static int vf610_read_raw(struct iio_dev *indio_dev,
break;
case IIO_TEMP:
/*
- * Calculate in degree Celsius times 1000
- * Using sensor slope of 1.84 mV/ÂC and
- * V at 25ÂC of 696 mV
- */
- *val = 25000 - ((int)info->value - 864) * 1000000 / 1840;
+ * Calculate in degree Celsius times 1000
+ * Using the typical sensor slope of 1.84 mV/ÂC
+ * and VREFH_ADC at 3.3V, V at 25ÂC of 699 mV
+ */
+ *val = 25000 - ((int)info->value - VF610_VTEMP25_3V3) *
+ 1000000 / VF610_TEMP_SLOPE_COEFF;
+
break;
default:
mutex_unlock(&indio_dev->mlock);
--
1.9.1

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/