[PATCH 02/18] clk: samsung: exynos3250: Move platform driver and of_device_id to init section

From: Krzysztof Kozlowski
Date: Wed May 11 2016 - 08:07:33 EST


The platform_driver and of_device_id structs can be moved to init
section because they are referenced only from subsys_initcall-level
function.

Signed-off-by: Krzysztof Kozlowski <k.kozlowski@xxxxxxxxxxx>
---
drivers/clk/samsung/clk-exynos3250.c | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/clk/samsung/clk-exynos3250.c b/drivers/clk/samsung/clk-exynos3250.c
index 16575ee874cb..e26b04fea33b 100644
--- a/drivers/clk/samsung/clk-exynos3250.c
+++ b/drivers/clk/samsung/clk-exynos3250.c
@@ -1079,12 +1079,12 @@ static int __init exynos3250_cmu_isp_probe(struct platform_device *pdev)
return 0;
}

-static const struct of_device_id exynos3250_cmu_isp_of_match[] = {
+static const struct of_device_id exynos3250_cmu_isp_of_match[] __initconst = {
{ .compatible = "samsung,exynos3250-cmu-isp", },
{ /* sentinel */ }
};

-static struct platform_driver exynos3250_cmu_isp_driver = {
+static struct platform_driver exynos3250_cmu_isp_driver __initdata = {
.driver = {
.name = "exynos3250-cmu-isp",
.of_match_table = exynos3250_cmu_isp_of_match,
--
1.9.1