On Fri, Dec 16, 2016 at 10:44:00AM +0100, Peter Rosin wrote:
> The ACOK pin on the bq24735 is active-high, of course meaning that when
> AC is OK the pin is high. However, all Tegra dts files have incorrectly
> specified active-high even though the signal is inverted on the Tegra
> boards. This has worked since the Linux driver has also inverted the
> meaning of the GPIO. Fix this situation by simply specifying in the
> bindings what everybody else agrees on; that the ti,ac-detect-gpios is
> active on AC adapter absence.
>
> Signed-off-by: Peter Rosin <peda@xxxxxxxxxx>
Thanks for your patch. We are currently in the merge
window and your patch will appear in linux-next once
4.10-rc1 has been tagged by Linus Torvalds.
Until then I queued it into this branch:
https://git.kernel.org/cgit/linux/kernel/git/sre/linux-power-supply.git/log/?h=for-next-next
-- Sebastian