[PATCH v2 16/31] usb/phy-isp1301-omap: Remove .data assignment

From: Kees Cook
Date: Wed Sep 20 2017 - 19:29:54 EST


The .data assignment appears to be redundant to the WORK_STOP bit for
stopping the timer. Also, it appears this timer is entirely unused
as it is only ever started under #define VERBOSE, which is explicitly
undefined.

Cc: Felipe Balbi <balbi@xxxxxxxxxx>
Cc: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>
Cc: linux-usb@xxxxxxxxxxxxxxx
Cc: linux-omap@xxxxxxxxxxxxxxx
Signed-off-by: Kees Cook <keescook@xxxxxxxxxxxx>
---
drivers/usb/phy/phy-isp1301-omap.c | 1 -
1 file changed, 1 deletion(-)

diff --git a/drivers/usb/phy/phy-isp1301-omap.c b/drivers/usb/phy/phy-isp1301-omap.c
index 5630840b77b1..8a07ce63b92d 100644
--- a/drivers/usb/phy/phy-isp1301-omap.c
+++ b/drivers/usb/phy/phy-isp1301-omap.c
@@ -1222,7 +1222,6 @@ static int isp1301_remove(struct i2c_client *i2c)
if (machine_is_omap_h2())
gpio_free(2);

- isp->timer.data = 0;
set_bit(WORK_STOP, &isp->todo);
del_timer_sync(&isp->timer);
flush_work(&isp->work);
--
2.7.4