Re: [PATCH v7 09/14] dt-bindings: iommu/rockchip: Add clock property

From: Robin Murphy
Date: Wed Mar 07 2018 - 08:01:49 EST


On 06/03/18 03:21, Jeffy Chen wrote:
Add clock property, since we are going to control clocks in rockchip
iommu driver.

Reviewed-by: Robin Murphy <robin.murphy@xxxxxxx>

Signed-off-by: Jeffy Chen <jeffy.chen@xxxxxxxxxxxxxx>
Reviewed-by: Rob Herring <robh@xxxxxxxxxx>
---

Changes in v7: None
Changes in v6:
Fix dt-binding as Robin suggested.
Use aclk and iface clk as Rob and Robin suggested, and split binding
patch.

Changes in v5: None
Changes in v4: None
Changes in v3: None
Changes in v2: None

Documentation/devicetree/bindings/iommu/rockchip,iommu.txt | 7 +++++++
1 file changed, 7 insertions(+)

diff --git a/Documentation/devicetree/bindings/iommu/rockchip,iommu.txt b/Documentation/devicetree/bindings/iommu/rockchip,iommu.txt
index 2098f7732264..6ecefea1c6f9 100644
--- a/Documentation/devicetree/bindings/iommu/rockchip,iommu.txt
+++ b/Documentation/devicetree/bindings/iommu/rockchip,iommu.txt
@@ -14,6 +14,11 @@ Required properties:
"single-master" device, and needs no additional information
to associate with its master device. See:
Documentation/devicetree/bindings/iommu/iommu.txt
+- clocks : A list of clocks required for the IOMMU to be accessible by
+ the host CPU.
+- clock-names : Should contain the following:
+ "iface" - Main peripheral bus clock (PCLK/HCL) (required)
+ "aclk" - AXI bus clock (required)
Optional properties:
- rockchip,disable-mmu-reset : Don't use the mmu reset operation.
@@ -27,5 +32,7 @@ Example:
reg = <0xff940300 0x100>;
interrupts = <GIC_SPI 16 IRQ_TYPE_LEVEL_HIGH>;
interrupt-names = "vopl_mmu";
+ clocks = <&cru ACLK_VOP1>, <&cru HCLK_VOP1>;
+ clock-names = "aclk", "iface";
#iommu-cells = <0>;
};