[RFC PATCH 09/09] Introduce cache=rdma moutning option

From: Long Li
Date: Thu May 17 2018 - 19:28:09 EST


From: Long Li <longli@xxxxxxxxxxxxx>

When cache=rdma is enabled on mount options, CIFS do not allocate internal data
buffer pages for I/O, data is read/writen directly to user memory via RDMA.

Signed-off-by: Long Li <longli@xxxxxxxxxxxxx>
---
fs/cifs/cifs_fs_sb.h | 2 ++
fs/cifs/cifsglob.h | 1 +
fs/cifs/connect.c | 9 +++++++++
fs/cifs/dir.c | 5 +++++
fs/cifs/file.c | 4 ++++
fs/cifs/inode.c | 4 +++-
6 files changed, 24 insertions(+), 1 deletion(-)

diff --git a/fs/cifs/cifs_fs_sb.h b/fs/cifs/cifs_fs_sb.h
index 350fa55..7c28dc3 100644
--- a/fs/cifs/cifs_fs_sb.h
+++ b/fs/cifs/cifs_fs_sb.h
@@ -51,6 +51,8 @@
*/
#define CIFS_MOUNT_UID_FROM_ACL 0x2000000 /* try to get UID via special SID */

+#define CIFS_MOUNT_DIRECT_RDMA 0x4000000
+
struct cifs_sb_info {
struct rb_root tlink_tree;
spinlock_t tlink_tree_lock;
diff --git a/fs/cifs/cifsglob.h b/fs/cifs/cifsglob.h
index a51855c..3bec63f 100644
--- a/fs/cifs/cifsglob.h
+++ b/fs/cifs/cifsglob.h
@@ -518,6 +518,7 @@ struct smb_vol {
bool server_ino:1; /* use inode numbers from server ie UniqueId */
bool direct_io:1;
bool strict_io:1; /* strict cache behavior */
+ bool rdma_io:1;
bool remap:1; /* set to remap seven reserved chars in filenames */
bool sfu_remap:1; /* remap seven reserved chars ala SFU */
bool posix_paths:1; /* unset to not ask for posix pathnames. */
diff --git a/fs/cifs/connect.c b/fs/cifs/connect.c
index 46d0cf4..c92b3d8 100644
--- a/fs/cifs/connect.c
+++ b/fs/cifs/connect.c
@@ -282,6 +282,7 @@ enum {
Opt_cache_loose,
Opt_cache_strict,
Opt_cache_none,
+ Opt_cache_rdma,
Opt_cache_err
};

@@ -289,6 +290,7 @@ static const match_table_t cifs_cacheflavor_tokens = {
{ Opt_cache_loose, "loose" },
{ Opt_cache_strict, "strict" },
{ Opt_cache_none, "none" },
+ { Opt_cache_rdma, "rdma" },
{ Opt_cache_err, NULL }
};

@@ -1128,6 +1130,9 @@ cifs_parse_cache_flavor(char *value, struct smb_vol *vol)
vol->direct_io = true;
vol->strict_io = false;
break;
+ case Opt_cache_rdma:
+ vol->rdma_io = true;
+ break;
default:
cifs_dbg(VFS, "bad cache= option: %s\n", value);
return 1;
@@ -3612,6 +3617,10 @@ int cifs_setup_cifs_sb(struct smb_vol *pvolume_info,
cifs_dbg(FYI, "mounting share using direct i/o\n");
cifs_sb->mnt_cifs_flags |= CIFS_MOUNT_DIRECT_IO;
}
+ if (pvolume_info->rdma_io) {
+ cifs_dbg(VFS, "mounting share using rdma i/o\n");
+ cifs_sb->mnt_cifs_flags |= CIFS_MOUNT_DIRECT_RDMA;
+ }
if (pvolume_info->mfsymlinks) {
if (pvolume_info->sfu_emul) {
/*
diff --git a/fs/cifs/dir.c b/fs/cifs/dir.c
index 81ba6e0..ce69b1c 100644
--- a/fs/cifs/dir.c
+++ b/fs/cifs/dir.c
@@ -557,6 +557,11 @@ cifs_atomic_open(struct inode *inode, struct dentry *direntry,
file->f_op = &cifs_file_direct_ops;
}

+ if (file->f_flags & O_DIRECT &&
+ CIFS_SB(inode->i_sb)->mnt_cifs_flags & CIFS_MOUNT_DIRECT_RDMA)
+ file->f_op = &cifs_file_direct_rdma_ops;
+
+
file_info = cifs_new_fileinfo(&fid, file, tlink, oplock);
if (file_info == NULL) {
if (server->ops->close)
diff --git a/fs/cifs/file.c b/fs/cifs/file.c
index 0b394db..30ccf6a 100644
--- a/fs/cifs/file.c
+++ b/fs/cifs/file.c
@@ -492,6 +492,10 @@ int cifs_open(struct inode *inode, struct file *file)
file->f_op = &cifs_file_direct_ops;
}

+ if (file->f_flags & O_DIRECT &&
+ cifs_sb->mnt_cifs_flags & CIFS_MOUNT_DIRECT_RDMA)
+ file->f_op = &cifs_file_direct_rdma_ops;
+
if (server->oplocks)
oplock = REQ_OPLOCK;
else
diff --git a/fs/cifs/inode.c b/fs/cifs/inode.c
index 3c371f7..7991298 100644
--- a/fs/cifs/inode.c
+++ b/fs/cifs/inode.c
@@ -44,7 +44,9 @@ static void cifs_set_ops(struct inode *inode)
switch (inode->i_mode & S_IFMT) {
case S_IFREG:
inode->i_op = &cifs_file_inode_ops;
- if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_DIRECT_IO) {
+ if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_DIRECT_RDMA)
+ inode->i_fop = &cifs_file_direct_rdma_ops;
+ else if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_DIRECT_IO) {
if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_NO_BRL)
inode->i_fop = &cifs_file_direct_nobrl_ops;
else
--
2.7.4