Re: [PATCH 42/46] perf script powerpc: Python script for hypervisor call statistics

From: Paul Clarke
Date: Wed Jun 06 2018 - 10:53:33 EST


On 06/05/2018 12:50 PM, Arnaldo Carvalho de Melo wrote:
> From: Ravi Bangoria <ravi.bangoria@xxxxxxxxxxxxx>
>
> Add python script to show hypervisor call statistics. Ex,
>
> # perf record -a -e "{powerpc:hcall_entry,powerpc:hcall_exit}"
> # perf script -s scripts/python/powerpc-hcalls.py
> hcall count min(ns) max(ns) avg(ns)
> --------------------------------------------------------------------
> H_RANDOM 82 838 1164 904
> H_PUT_TCE 47 1078 5928 2003
> H_EOI 266 1336 3546 1654
> H_ENTER 28 1646 4038 1952
> H_PUT_TCE_INDIRECT 230 2166 18168 6109
> H_IPI 238 1072 3232 1688
> H_SEND_LOGICAL_LAN 42 5488 21366 7694
> H_STUFF_TCE 294 986 6210 3591
> H_XIRR 266 2286 6990 3783
> H_PROTECT 10 2196 3556 2555
> H_VIO_SIGNAL 294 1028 2784 1311
> H_ADD_LOGICAL_LAN_BUFFER 53 1978 3450 2600
> H_SEND_CRQ 77 1762 7240 2447

This translation from HCALL code to mnemonic is more generally useful. Is there a good way to make the "hcall_table_lookup" function more generally available, like "syscall_name" in scripts/python/Perf-Trace-Util/lib/Perf/Trace/Util.py ? It's even simpler than the syscall ID-to-name mapping, because the HCALL codes are constant, unlike syscall IDs which vary between arches.

> diff --git a/tools/perf/scripts/python/powerpc-hcalls.py b/tools/perf/scripts/python/powerpc-hcalls.py
> new file mode 100644
> index 000000000000..00e0e7476e55
> --- /dev/null
> +++ b/tools/perf/scripts/python/powerpc-hcalls.py
> @@ -0,0 +1,200 @@
> +# SPDX-License-Identifier: GPL-2.0+
> +#
> +# Copyright (C) 2018 Ravi Bangoria, IBM Corporation
> +#
> +# Hypervisor call statisics
> +
> +import os
> +import sys
> +
> +sys.path.append(os.environ['PERF_EXEC_PATH'] + \
> + '/scripts/python/Perf-Trace-Util/lib/Perf/Trace')
> +
> +from perf_trace_context import *
> +from Core import *
> +from Util import *
> +
> +# output: {
> +# opcode: {
> +# 'min': minimum time nsec
> +# 'max': maximum time nsec
> +# 'time': average time nsec
> +# 'cnt': counter
> +# } ...
> +# }
> +output = {}
> +
> +# d_enter: {
> +# cpu: {
> +# opcode: nsec
> +# } ...
> +# }
> +d_enter = {}
> +
> +hcall_table = {
> + 4: 'H_REMOVE',
> + 8: 'H_ENTER',
> + 12: 'H_READ',
> + 16: 'H_CLEAR_MOD',
> + 20: 'H_CLEAR_REF',
> + 24: 'H_PROTECT',
> + 28: 'H_GET_TCE',
> + 32: 'H_PUT_TCE',
> + 36: 'H_SET_SPRG0',
> + 40: 'H_SET_DABR',
> + 44: 'H_PAGE_INIT',
> + 48: 'H_SET_ASR',
> + 52: 'H_ASR_ON',
> + 56: 'H_ASR_OFF',
> + 60: 'H_LOGICAL_CI_LOAD',
> + 64: 'H_LOGICAL_CI_STORE',
> + 68: 'H_LOGICAL_CACHE_LOAD',
> + 72: 'H_LOGICAL_CACHE_STORE',
> + 76: 'H_LOGICAL_ICBI',
> + 80: 'H_LOGICAL_DCBF',
> + 84: 'H_GET_TERM_CHAR',
> + 88: 'H_PUT_TERM_CHAR',
> + 92: 'H_REAL_TO_LOGICAL',
> + 96: 'H_HYPERVISOR_DATA',
> + 100: 'H_EOI',
> + 104: 'H_CPPR',
> + 108: 'H_IPI',
> + 112: 'H_IPOLL',
> + 116: 'H_XIRR',
> + 120: 'H_MIGRATE_DMA',
> + 124: 'H_PERFMON',
> + 220: 'H_REGISTER_VPA',
> + 224: 'H_CEDE',
> + 228: 'H_CONFER',
> + 232: 'H_PROD',
> + 236: 'H_GET_PPP',
> + 240: 'H_SET_PPP',
> + 244: 'H_PURR',
> + 248: 'H_PIC',
> + 252: 'H_REG_CRQ',
> + 256: 'H_FREE_CRQ',
> + 260: 'H_VIO_SIGNAL',
> + 264: 'H_SEND_CRQ',
> + 272: 'H_COPY_RDMA',
> + 276: 'H_REGISTER_LOGICAL_LAN',
> + 280: 'H_FREE_LOGICAL_LAN',
> + 284: 'H_ADD_LOGICAL_LAN_BUFFER',
> + 288: 'H_SEND_LOGICAL_LAN',
> + 292: 'H_BULK_REMOVE',
> + 304: 'H_MULTICAST_CTRL',
> + 308: 'H_SET_XDABR',
> + 312: 'H_STUFF_TCE',
> + 316: 'H_PUT_TCE_INDIRECT',
> + 332: 'H_CHANGE_LOGICAL_LAN_MAC',
> + 336: 'H_VTERM_PARTNER_INFO',
> + 340: 'H_REGISTER_VTERM',
> + 344: 'H_FREE_VTERM',
> + 348: 'H_RESET_EVENTS',
> + 352: 'H_ALLOC_RESOURCE',
> + 356: 'H_FREE_RESOURCE',
> + 360: 'H_MODIFY_QP',
> + 364: 'H_QUERY_QP',
> + 368: 'H_REREGISTER_PMR',
> + 372: 'H_REGISTER_SMR',
> + 376: 'H_QUERY_MR',
> + 380: 'H_QUERY_MW',
> + 384: 'H_QUERY_HCA',
> + 388: 'H_QUERY_PORT',
> + 392: 'H_MODIFY_PORT',
> + 396: 'H_DEFINE_AQP1',
> + 400: 'H_GET_TRACE_BUFFER',
> + 404: 'H_DEFINE_AQP0',
> + 408: 'H_RESIZE_MR',
> + 412: 'H_ATTACH_MCQP',
> + 416: 'H_DETACH_MCQP',
> + 420: 'H_CREATE_RPT',
> + 424: 'H_REMOVE_RPT',
> + 428: 'H_REGISTER_RPAGES',
> + 432: 'H_DISABLE_AND_GETC',
> + 436: 'H_ERROR_DATA',
> + 440: 'H_GET_HCA_INFO',
> + 444: 'H_GET_PERF_COUNT',
> + 448: 'H_MANAGE_TRACE',
> + 468: 'H_FREE_LOGICAL_LAN_BUFFER',
> + 472: 'H_POLL_PENDING',
> + 484: 'H_QUERY_INT_STATE',
> + 580: 'H_ILLAN_ATTRIBUTES',
> + 592: 'H_MODIFY_HEA_QP',
> + 596: 'H_QUERY_HEA_QP',
> + 600: 'H_QUERY_HEA',
> + 604: 'H_QUERY_HEA_PORT',
> + 608: 'H_MODIFY_HEA_PORT',
> + 612: 'H_REG_BCMC',
> + 616: 'H_DEREG_BCMC',
> + 620: 'H_REGISTER_HEA_RPAGES',
> + 624: 'H_DISABLE_AND_GET_HEA',
> + 628: 'H_GET_HEA_INFO',
> + 632: 'H_ALLOC_HEA_RESOURCE',
> + 644: 'H_ADD_CONN',
> + 648: 'H_DEL_CONN',
> + 664: 'H_JOIN',
> + 676: 'H_VASI_STATE',
> + 688: 'H_ENABLE_CRQ',
> + 696: 'H_GET_EM_PARMS',
> + 720: 'H_SET_MPP',
> + 724: 'H_GET_MPP',
> + 748: 'H_HOME_NODE_ASSOCIATIVITY',
> + 756: 'H_BEST_ENERGY',
> + 764: 'H_XIRR_X',
> + 768: 'H_RANDOM',
> + 772: 'H_COP',
> + 788: 'H_GET_MPP_X',
> + 796: 'H_SET_MODE',
> + 61440: 'H_RTAS',
> +}
> +
> +def hcall_table_lookup(opcode):
> + if (hcall_table.has_key(opcode)):
> + return hcall_table[opcode]
> + else:
> + return opcode
> +
> +print_ptrn = '%-28s%10s%10s%10s%10s'
> +
> +def trace_end():
> + print print_ptrn % ('hcall', 'count', 'min(ns)', 'max(ns)', 'avg(ns)')
> + print '-' * 68
> + for opcode in output:
> + h_name = hcall_table_lookup(opcode)
> + time = output[opcode]['time']
> + cnt = output[opcode]['cnt']
> + min_t = output[opcode]['min']
> + max_t = output[opcode]['max']
> +
> + print print_ptrn % (h_name, cnt, min_t, max_t, time/cnt)
> +
> +def powerpc__hcall_exit(name, context, cpu, sec, nsec, pid, comm, callchain,
> + opcode, retval):
> + if (d_enter.has_key(cpu) and d_enter[cpu].has_key(opcode)):
> + diff = nsecs(sec, nsec) - d_enter[cpu][opcode]
> +
> + if (output.has_key(opcode)):
> + output[opcode]['time'] += diff
> + output[opcode]['cnt'] += 1
> + if (output[opcode]['min'] > diff):
> + output[opcode]['min'] = diff
> + if (output[opcode]['max'] < diff):
> + output[opcode]['max'] = diff
> + else:
> + output[opcode] = {
> + 'time': diff,
> + 'cnt': 1,
> + 'min': diff,
> + 'max': diff,
> + }
> +
> + del d_enter[cpu][opcode]
> +# else:
> +# print "Can't find matching hcall_enter event. Ignoring sample"
> +
> +def powerpc__hcall_entry(event_name, context, cpu, sec, nsec, pid, comm,
> + callchain, opcode):
> + if (d_enter.has_key(cpu)):
> + d_enter[cpu][opcode] = nsecs(sec, nsec)
> + else:
> + d_enter[cpu] = {opcode: nsecs(sec, nsec)}
>

PC