Re: [PATCH v2 0/3] mtd: rawnand: denali: add new clocks and improve setup_data_interface

From: Richard Weinberger
Date: Thu Jun 14 2018 - 04:02:23 EST


Am Donnerstag, 14. Juni 2018, 09:38:35 CEST schrieb Boris Brezillon:
> On Thu, 14 Jun 2018 16:29:59 +0900
> Masahiro Yamada <yamada.masahiro@xxxxxxxxxxxxx> wrote:
>
> > Hi Richard,
> >
> > 2018-06-14 16:25 GMT+09:00 Richard Weinberger <richard@xxxxxxxxxxxxx>:
> > > Masahiro,
> > >
> > > Am Donnerstag, 14. Juni 2018, 07:11:04 CEST schrieb Masahiro Yamada:
> > >>
> > >> The ->setup_data_interface() hook needs to know the clock frequency.
> > >> In fact, this IP needs three clocks, bus "which clock?" is really
> > >> confusing. (It is not described in the DT-binding at all.)
> > >>
> > >> This series adds more clocks. In the new binding, three clocks
> > >> are required: core clock, bus interface clock, ECC engine clock.
> > >>
> > >> This series also takes care of the backward compatibility by
> > >> providing hardcoded values in case the new clocks are missing.
> > >> So, existing DT should work.
> > >>
> > >>
> > >> Changes in v2:
> > >> - Split patches into sensible chunks
> > >>
> > >> Masahiro Yamada (3):
> > >> mtd: rawnand: denali_dt: use dev as a shorthand of &pdev->dev
> > >> mtd: rawnand: denali_dt: add more clocks based on IP datasheet
> > >> mtd: rawnand: denali: optimize timing parameters for data interface
> > >
> > > This still means that we need to feed at least 2/3 and 3/3 into -stable to
> > > unbreak the driver.
> >
> >
> > 3/3 is not mandatory.
> >
> > You can only back-port 1/3 and 2/3.
>
> Well, patch 1 is not a fix, can we move it after patch 2 so that only
> patch 2 is flagged with the Fixes+Cc-stable tags?

Another question, shall we fix arch/arm/boot/dts/socfpga.dtsi too?

Thanks,
//richard

--
sigma star gmbh - Eduard-Bodem-Gasse 6 - 6020 Innsbruck - Austria
ATU66964118 - FN 374287y