[PATCH v1 1/4] thermal: tegra: continue if sensor register fails

From: Wei Ni
Date: Mon Nov 05 2018 - 04:33:10 EST


Don't bail when a sensor fails to register with the
thermal zone and allow other sensors to register.
This allows other sensors to register with thermal
framework even if one sensor fails registration.

Signed-off-by: Wei Ni <wni@xxxxxxxxxx>
---
drivers/thermal/tegra/soctherm.c | 6 ++++--
1 file changed, 4 insertions(+), 2 deletions(-)

diff --git a/drivers/thermal/tegra/soctherm.c b/drivers/thermal/tegra/soctherm.c
index ed28110a3535..b708300303ff 100644
--- a/drivers/thermal/tegra/soctherm.c
+++ b/drivers/thermal/tegra/soctherm.c
@@ -1370,9 +1370,9 @@ static int tegra_soctherm_probe(struct platform_device *pdev)
&tegra_of_thermal_ops);
if (IS_ERR(z)) {
err = PTR_ERR(z);
- dev_err(&pdev->dev, "failed to register sensor: %d\n",
+ dev_warn(&pdev->dev, "failed to register sensor: %d\n",
err);
- goto disable_clocks;
+ continue;
}

zone->tz = z;
@@ -1434,6 +1434,8 @@ static int __maybe_unused soctherm_resume(struct device *dev)
struct thermal_zone_device *tz;

tz = tegra->thermctl_tzs[soc->ttgs[i]->id];
+ if (!tz)
+ continue;
err = tegra_soctherm_set_hwtrips(dev, soc->ttgs[i], tz);
if (err) {
dev_err(&pdev->dev,
--
2.7.4