[PATCH] power: supply: charger-manager: Fix trivial language typos

From: Krzysztof Kozlowski
Date: Tue Jan 08 2019 - 07:12:37 EST


Fix few trivial language typos.

Signed-off-by: Krzysztof Kozlowski <krzk@xxxxxxxxxx>
---
drivers/power/supply/charger-manager.c | 18 +++++++++---------
1 file changed, 9 insertions(+), 9 deletions(-)

diff --git a/drivers/power/supply/charger-manager.c b/drivers/power/supply/charger-manager.c
index 38be91f21cc4..2e8db5e6de0b 100644
--- a/drivers/power/supply/charger-manager.c
+++ b/drivers/power/supply/charger-manager.c
@@ -4,7 +4,7 @@
*
* This driver enables to monitor battery health and control charger
* during suspend-to-mem.
- * Charger manager depends on other devices. register this later than
+ * Charger manager depends on other devices. Register this later than
* the depending devices.
*
* This program is free software; you can redistribute it and/or modify
@@ -29,7 +29,7 @@
#include <linux/thermal.h>

/*
- * Default termperature threshold for charging.
+ * Default temperature threshold for charging.
* Every temperature units are in tenth of centigrade.
*/
#define CM_DEFAULT_RECHARGE_TEMP_DIFF 50
@@ -356,7 +356,7 @@ static bool is_polling_required(struct charger_manager *cm)
* Note that Charger Manager keeps the charger enabled regardless whether
* the charger is charging or not (because battery is full or no external
* power source exists) except when CM needs to disable chargers forcibly
- * bacause of emergency causes; when the battery is overheated or too cold.
+ * because of emergency causes; when the battery is overheated or too cold.
*/
static int try_charger_enable(struct charger_manager *cm, bool enable)
{
@@ -643,7 +643,7 @@ static int cm_check_thermal_status(struct charger_manager *cm)
if (ret) {
/* FIXME:
* No information of battery temperature might
- * occur hazadous result. We have to handle it
+ * occur hazardous result. We have to handle it
* depending on battery type.
*/
dev_err(cm->dev, "Failed to get battery temperature\n");
@@ -693,7 +693,7 @@ static bool _cm_monitor(struct charger_manager *cm)
uevent_notify(cm, default_event_names[temp_alrt]);

/*
- * Check whole charging duration and discharing duration
+ * Check whole charging duration and discharging duration
* after full-batt.
*/
} else if (!cm->emergency_stop && check_charging_duration(cm)) {
@@ -866,7 +866,7 @@ static void battout_handler(struct charger_manager *cm)
}

/**
- * misc_event_handler - Handler for other evnets
+ * misc_event_handler - Handler for other events
* @cm: the Charger Manager representing the battery.
* @type: the Charger Manager representing the battery.
*/
@@ -1218,7 +1218,7 @@ static int charger_extcon_init(struct charger_manager *cm,
}

/**
- * charger_manager_register_extcon - Register extcon device to recevie state
+ * charger_manager_register_extcon - Register extcon device to receive state
* of charger cable.
* @cm: the Charger Manager representing the battery.
*
@@ -1538,7 +1538,7 @@ static struct charger_desc *of_cm_parse_desc(struct device *dev)
of_property_read_u32(np, "cm-discharging-max",
&desc->discharging_max_duration_ms);

- /* battery charger regualtors */
+ /* battery charger regulators */
desc->num_charger_regulators = of_get_child_count(np);
if (desc->num_charger_regulators) {
struct charger_regulator *chg_regs;
@@ -1801,7 +1801,7 @@ static int charger_manager_probe(struct platform_device *pdev)

/*
* Charger-manager have to check the charging state right after
- * tialization of charger-manager and then update current charging
+ * initialization of charger-manager and then update current charging
* state.
*/
cm_monitor();
--
2.7.4