Re: [PATCH 3/7] coresight: Use event attributes for sink selection

From: Suzuki K Poulose
Date: Thu Jan 17 2019 - 12:33:45 EST


Hi Mathieu,

On 16/01/2019 23:57, Mathieu Poirier wrote:
On Wed, 16 Jan 2019 at 03:36, Suzuki K Poulose <suzuki.poulose@xxxxxxx> wrote:

Hi Mathieu,

On 15/01/2019 23:07, Mathieu Poirier wrote:
This patch uses the information conveyed by perf_event::attr::config2
to select a sink to use for the session. That way a sink can easily be
selected to be used by more than one source, something that isn't currently
possible with the sysfs implementation.

Signed-off-by: Mathieu Poirier <mathieu.poirier@xxxxxxxxxx>
---
.../hwtracing/coresight/coresight-etm-perf.c | 16 ++------
drivers/hwtracing/coresight/coresight-priv.h | 1 +
drivers/hwtracing/coresight/coresight.c | 39 +++++++++++++++++++
3 files changed, 44 insertions(+), 12 deletions(-)

diff --git a/drivers/hwtracing/coresight/coresight-etm-perf.c b/drivers/hwtracing/coresight/coresight-etm-perf.c
index 292bd409a68c..685d16001d0b 100644
--- a/drivers/hwtracing/coresight/coresight-etm-perf.c
+++ b/drivers/hwtracing/coresight/coresight-etm-perf.c
@@ -201,18 +201,10 @@ static void *etm_setup_aux(struct perf_event *event, void **pages,
return NULL;
INIT_WORK(&event_data->work, free_event_data);

- /*
- * In theory nothing prevent tracers in a trace session from being
- * associated with different sinks, nor having a sink per tracer. But
- * until we have HW with this kind of topology we need to assume tracers
- * in a trace session are using the same sink. Therefore go through
- * the coresight bus and pick the first enabled sink.
- *
- * When operated from sysFS users are responsible to enable the sink
- * while from perf, the perf tools will do it based on the choice made
- * on the cmd line. As such the "enable_sink" flag in sysFS is reset.
- */
- sink = coresight_get_enabled_sink(true);
+ /* First get the selected sink from user space. */
+ sink = coresight_get_sink_by_id(event->attr.config2);

Please could we also expose this information under "format", so that the
userspace knows where to fill in the sink id ? The other advantage is, we
could always change the size of the sink_id with the above, if we decide
to do something different with the sinks.

Humm... From my point of view we don't want user space to do anything
with the sink ID other than read it. In what scenario do envison
user space filling the sink ID?

The userspace needs to know where to put the "sink_id" in. (in this case
the driver expects it in attr.config2). So having this exposed in "format"
helps us to expose this information to all users (not just the perf tool, where
we hard-code it).

diff --git a/drivers/hwtracing/coresight/coresight-priv.h b/drivers/hwtracing/coresight/coresight-priv.h
index 579f34943bf1..071bb98d358f 100644
--- a/drivers/hwtracing/coresight/coresight-priv.h
+++ b/drivers/hwtracing/coresight/coresight-priv.h
@@ -147,6 +147,7 @@ void coresight_disable_path(struct list_head *path);
int coresight_enable_path(struct list_head *path, u32 mode, void *sink_data);
struct coresight_device *coresight_get_sink(struct list_head *path);
struct coresight_device *coresight_get_enabled_sink(bool reset);
+struct coresight_device *coresight_get_sink_by_id(u64 id);
struct list_head *coresight_build_path(struct coresight_device *csdev,
struct coresight_device *sink);
void coresight_release_path(struct list_head *path);
diff --git a/drivers/hwtracing/coresight/coresight.c b/drivers/hwtracing/coresight/coresight.c
index 526f122a38ee..7e2ce0beb2a0 100644
--- a/drivers/hwtracing/coresight/coresight.c
+++ b/drivers/hwtracing/coresight/coresight.c
@@ -11,6 +11,7 @@
#include <linux/err.h>
#include <linux/export.h>
#include <linux/slab.h>
+#include <linux/stringhash.h>
#include <linux/mutex.h>
#include <linux/clk.h>
#include <linux/coresight.h>
@@ -541,6 +542,44 @@ struct coresight_device *coresight_get_enabled_sink(bool deactivate)
return dev ? to_coresight_device(dev) : NULL;
}

+static int coresight_sink_by_id(struct device *dev, void *data)
+{
+ struct coresight_device *csdev = to_coresight_device(dev);
+ unsigned long hash;
+
+ if (csdev->type == CORESIGHT_DEV_TYPE_SINK ||
+ csdev->type == CORESIGHT_DEV_TYPE_LINKSINK) {
+ /*
+ * See function etm_perf_sink_name_show() to know where this
+ * comes from.
+ */
+ hash = hashlen_hash(hashlen_string(NULL, dev_name(dev)));
+
+ if (hash == (*(unsigned long *)data))
+ return 1;

nit: is it worth storing the sink_id of a sink in the csdev ? May be if we add
attribute field to the csdev (as mentioned in the previous patch), we could
simply use it here to compare.

That depends on what we end up doing in the previous patch (see my
comment). Since we are not even close to modularize coresight drivers
(unless you're already spending your weekends working on that,
something I doubt very much :o) ) I don't think we need to go this
way. Again, let me know if you really want me to change this.

As I said, I understand the complexity of the modularization effort. However
it would be good to be future proof than figure this out the hard way when we
get there and we don't loose much except a few bytes in the coresight_device.

Cheers
Suzuki