Re: [PATCH v2 2/4] dt-bindings: power: supply: Max17040: Add low level SOC alert threshold

From: Rob Herring
Date: Mon Apr 29 2019 - 18:13:59 EST


On Sun, Apr 14, 2019 at 10:26:33PM -0300, Matheus Castello wrote:
> For configure low level state of charge threshold alert signaled from
> max17040 we add "maxim,alert-soc-level" property.
>
> Signed-off-by: Matheus Castello <matheus@xxxxxxxxxxxxxxx>
> ---
> .../power/supply/max17040_battery.txt | 24 +++++++++++++++++++
> 1 file changed, 24 insertions(+)
> create mode 100644 Documentation/devicetree/bindings/power/supply/max17040_battery.txt
>
> diff --git a/Documentation/devicetree/bindings/power/supply/max17040_battery.txt b/Documentation/devicetree/bindings/power/supply/max17040_battery.txt
> new file mode 100644
> index 000000000000..9b2cc67d556f
> --- /dev/null
> +++ b/Documentation/devicetree/bindings/power/supply/max17040_battery.txt
> @@ -0,0 +1,24 @@
> +max17040_battery
> +~~~~~~~~~~~~~~~~
> +
> +Required properties :
> + - compatible : "maxim,max17040" or "maxim,max77836-battery"

This is really a charger, not a battery.

> +
> +Optional properties :
> +- maxim,alert-soc-level : The alert threshold that sets the state of
> + charge level where an interrupt is generated.
> + Can be configured from 1 up to 32. If skipped
> + the power up default value of 4 will be used.

Units? This is a low or high alert? Does a common property make sense
here?

> +- interrupt-parent : The GPIO bank from the interrupt line.

Drop this. interrupt-parent is implied.

> +- interrupts : Interrupt line see Documentation/devicetree/
> + bindings/interrupt-controller/interrupts.txt
> +
> +Example:
> +
> + battery-charger@36 {
> + compatible = "maxim,max17040";
> + reg = <0x36>;
> + maxim,alert-soc-level = <10>;
> + interrupt-parent = <&gpio7>;
> + interrupts = <2 IRQ_TYPE_EDGE_FALLING>;

Usually there are battery properties that need to be described too...

> + };
> --
> 2.17.0
>