[PATCH 4.4 157/241] scsi: ufs: Avoid configuring regulator with undefined voltage range

From: Greg Kroah-Hartman
Date: Sun Jun 09 2019 - 13:07:07 EST


[ Upstream commit 3b141e8cfd54ba3e5c610717295b2a02aab26a05 ]

For regulators used by UFS, vcc, vccq and vccq2 will have voltage range
initialized by ufshcd_populate_vreg(), however other regulators may have
undefined voltage range if dt-bindings have no such definition.

In above undefined case, both "min_uV" and "max_uV" fields in ufs_vreg
struct will be zero values and these values will be configured on
regulators in different power modes.

Currently this may have no harm if both "min_uV" and "max_uV" always keep
"zero values" because regulator_set_voltage() will always bypass such
invalid values and return "good" results.

However improper values shall be fixed to avoid potential bugs. Simply
bypass voltage configuration if voltage range is not defined.

Signed-off-by: Stanley Chu <stanley.chu@xxxxxxxxxxxx>
Reviewed-by: Avri Altman <avri.altman@xxxxxxx>
Acked-by: Alim Akhtar <alim.akhtar@xxxxxxxxxxx>
Signed-off-by: Martin K. Petersen <martin.petersen@xxxxxxxxxx>
Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>
---
drivers/scsi/ufs/ufshcd.c | 13 ++++++++-----
1 file changed, 8 insertions(+), 5 deletions(-)

diff --git a/drivers/scsi/ufs/ufshcd.c b/drivers/scsi/ufs/ufshcd.c
index ed76381fce4cc..7322a17660d10 100644
--- a/drivers/scsi/ufs/ufshcd.c
+++ b/drivers/scsi/ufs/ufshcd.c
@@ -4434,12 +4434,15 @@ static int ufshcd_config_vreg(struct device *dev,
name = vreg->name;

if (regulator_count_voltages(reg) > 0) {
- min_uV = on ? vreg->min_uV : 0;
- ret = regulator_set_voltage(reg, min_uV, vreg->max_uV);
- if (ret) {
- dev_err(dev, "%s: %s set voltage failed, err=%d\n",
+ if (vreg->min_uV && vreg->max_uV) {
+ min_uV = on ? vreg->min_uV : 0;
+ ret = regulator_set_voltage(reg, min_uV, vreg->max_uV);
+ if (ret) {
+ dev_err(dev,
+ "%s: %s set voltage failed, err=%d\n",
__func__, name, ret);
- goto out;
+ goto out;
+ }
}

uA_load = on ? vreg->max_uA : 0;
--
2.20.1