[PATCH v13 00/13] Ingenic Timer/Counter Unit patchset v13

From: Paul Cercueil
Date: Mon Jun 24 2019 - 18:58:13 EST


Hi,

This is the version 13 of my patchset to support the Timer/Counter Unit
(TCU) present in JZ47xx SoCs from Ingenic.

Changelog:

Patch [03/13]:
- Revert back to v11. Turns out it was okay.
- Remove 'interrupt-parent' of the list of required properties.

Patch [05/13]:
- Don't enable/disable the TCU clock on demand. Enable it in the probe
and call it a day.
- Register suspend callbacks to gate/ungate the TCU clock on
suspend/resume.
- Use pr_fmt and pr_crit instead of custom TCU_ERR() macro
- Remove useless dependency on COMMON_CLK in Kconfig
- Remove registration of clkdev

All the other patches have not been modified.
The patchset was rebased on 5.2-rc6.

Cheers,
-Paul