[PATCH AUTOSEL 5.1 151/219] clocksource/drivers/tegra: Restore base address before cleanup

From: Sasha Levin
Date: Mon Jul 15 2019 - 10:13:00 EST


From: Dmitry Osipenko <digetx@xxxxxxxxx>

[ Upstream commit fc9babc2574691d3bbf0428f007b22261fed55c6 ]

We're adjusting the timer's base for each per-CPU timer to point to the
actual start of the timer since device-tree defines a compound registers
range that includes all of the timers. In this case the original base
need to be restore before calling iounmap to unmap the proper address.

Signed-off-by: Dmitry Osipenko <digetx@xxxxxxxxx>
Acked-by: Jon Hunter <jonathanh@xxxxxxxxxx>
Acked-by: Thierry Reding <treding@xxxxxxxxxx>
Signed-off-by: Daniel Lezcano <daniel.lezcano@xxxxxxxxxx>
Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>
---
drivers/clocksource/timer-tegra20.c | 2 ++
1 file changed, 2 insertions(+)

diff --git a/drivers/clocksource/timer-tegra20.c b/drivers/clocksource/timer-tegra20.c
index cc18bb135a17..84adfff59fb0 100644
--- a/drivers/clocksource/timer-tegra20.c
+++ b/drivers/clocksource/timer-tegra20.c
@@ -341,6 +341,8 @@ static int __init tegra_init_timer(struct device_node *np)
irq_dispose_mapping(cpu_to->clkevt.irq);
}
}
+
+ to->of_base.base = timer_reg_base;
out:
timer_of_cleanup(to);
return ret;
--
2.20.1