[PATCH v2] dt-bindings: arm-smmu: Add sc7180 compatible string and mem_iface clock

From: Sharat Masetty
Date: Thu Apr 30 2020 - 00:00:12 EST


This patch adds a new compatible string for sc7180 and also an
additional clock listing needed to power the TBUs and the TCU.

Signed-off-by: Sharat Masetty <smasetty@xxxxxxxxxxxxxx>
---
v2: Addressed review comments from Doug

Documentation/devicetree/bindings/iommu/arm,smmu.yaml | 8 ++++++++
1 file changed, 8 insertions(+)

diff --git a/Documentation/devicetree/bindings/iommu/arm,smmu.yaml b/Documentation/devicetree/bindings/iommu/arm,smmu.yaml
index 6515dbe..ba5dba4 100644
--- a/Documentation/devicetree/bindings/iommu/arm,smmu.yaml
+++ b/Documentation/devicetree/bindings/iommu/arm,smmu.yaml
@@ -28,6 +28,7 @@ properties:
- enum:
- qcom,msm8996-smmu-v2
- qcom,msm8998-smmu-v2
+ - qcom,sc7180-smmu-v2
- qcom,sdm845-smmu-v2
- const: qcom,smmu-v2

@@ -113,16 +114,23 @@ properties:
present in such cases.

clock-names:
+ minItems: 2
+ maxItems: 3
items:
- const: bus
- const: iface
+ - const: mem_iface

clocks:
+ minItems: 2
+ maxItems: 3
items:
- description: bus clock required for downstream bus access and for the
smmu ptw
- description: interface clock required to access smmu's registers
through the TCU's programming interface.
+ - description: clock required for the inner working of SMMU TBUs and the
+ TCU like the pagetable walks and the TLB flushes.

power-domains:
maxItems: 1
--
1.9.1