[PATCH] hwmon: fix corsair-psu fan rpm calculation

From: Wilken Gottwalt
Date: Fri Nov 13 2020 - 07:20:00 EST


The correct fan rpm value is also a LINEAR11 value but without a factor.
Verified by using the fan test button on the psu to let the fan spin up
to maximum for some seconds.

Fixes: 933222c98445 ("hwmon: (corsair-psu) fix unintentional sign extension issue")
Signed-off-by: Wilken Gottwalt <wilken.gottwalt@xxxxxxxxxx>
---
drivers/hwmon/corsair-psu.c | 7 +------
1 file changed, 1 insertion(+), 6 deletions(-)

diff --git a/drivers/hwmon/corsair-psu.c b/drivers/hwmon/corsair-psu.c
index 5d19a888231a..99494056f4bd 100644
--- a/drivers/hwmon/corsair-psu.c
+++ b/drivers/hwmon/corsair-psu.c
@@ -252,12 +252,7 @@ static int corsairpsu_get_value(struct corsairpsu_data *priv, u8 cmd, u8 rail, l
*val = corsairpsu_linear11_to_int(tmp & 0xFFFF) * 1000;
break;
case PSU_CMD_FAN:
- /*
- * this value is best guess, so the calculated value could be wrong, it is hard
- * to ge the fan to spin in these semi-passive power supplies, which need a
- * quite high load to do so
- */
- *val = ((tmp & 0xFF) << 8) + ((tmp >> 8) & 0xFF);
+ *val = corsairpsu_linear11_to_int(tmp & 0xFFFF);
break;
case PSU_CMD_RAIL_WATTS:
case PSU_CMD_TOTAL_WATTS:
--
2.29.2