[PATCH -next] phy: ingenic: Fix a typo in ingenic_usb_phy_probe()

From: 'Wei Yongjun
Date: Thu Mar 04 2021 - 22:40:52 EST


From: Wei Yongjun <weiyongjun1@xxxxxxxxxx>

Fix the return value check typo which testing the wrong variable
in ingenic_usb_phy_probe().

Fixes: 31de313dfdcf ("PHY: Ingenic: Add USB PHY driver using generic PHY framework.")
Reported-by: Hulk Robot <hulkci@xxxxxxxxxx>
Signed-off-by: Wei Yongjun <weiyongjun1@xxxxxxxxxx>
---
drivers/phy/ingenic/phy-ingenic-usb.c | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/phy/ingenic/phy-ingenic-usb.c b/drivers/phy/ingenic/phy-ingenic-usb.c
index ea127b177f46..28c28d816484 100644
--- a/drivers/phy/ingenic/phy-ingenic-usb.c
+++ b/drivers/phy/ingenic/phy-ingenic-usb.c
@@ -352,8 +352,8 @@ static int ingenic_usb_phy_probe(struct platform_device *pdev)
}

priv->phy = devm_phy_create(dev, NULL, &ingenic_usb_phy_ops);
- if (IS_ERR(priv))
- return PTR_ERR(priv);
+ if (IS_ERR(priv->phy))
+ return PTR_ERR(priv->phy);

phy_set_drvdata(priv->phy, priv);