[PATCHv2 27/38] dt-bindings: power: supply: act8945a: Convert to DT schema format

From: Sebastian Reichel
Date: Wed Mar 17 2021 - 09:57:02 EST


Convert the binding to DT schema format.

Signed-off-by: Sebastian Reichel <sebastian.reichel@xxxxxxxxxxxxx>
---
.../power/supply/act8945a-charger.txt | 44 -----------
.../supply/active-semi,act8945a-charger.yaml | 76 +++++++++++++++++++
2 files changed, 76 insertions(+), 44 deletions(-)
delete mode 100644 Documentation/devicetree/bindings/power/supply/act8945a-charger.txt
create mode 100644 Documentation/devicetree/bindings/power/supply/active-semi,act8945a-charger.yaml

diff --git a/Documentation/devicetree/bindings/power/supply/act8945a-charger.txt b/Documentation/devicetree/bindings/power/supply/act8945a-charger.txt
deleted file mode 100644
index cb737a9e1f16..000000000000
--- a/Documentation/devicetree/bindings/power/supply/act8945a-charger.txt
+++ /dev/null
@@ -1,44 +0,0 @@
-Device-Tree bindings for charger of Active-semi ACT8945A Multi-Function Device
-
-Required properties:
- - compatible: "active-semi,act8945a-charger".
- - active-semi,chglev-gpios: charge current level phandle with args
- as described in ../gpio/gpio.txt.
- - active-semi,lbo-gpios: specify the low battery voltage detect phandle
- with args as as described in ../gpio/gpio.txt.
- - interrupts: <a b> where a is the interrupt number and b is a
- field that represents an encoding of the sense and level
- information for the interrupt.
-
-Optional properties:
- - active-semi,input-voltage-threshold-microvolt: unit: mV;
- Specifies the charger's input over-voltage threshold value;
- The value can be: 6600, 7000, 7500, 8000; default: 6600
- - active-semi,precondition-timeout: unit: minutes;
- Specifies the charger's PRECONDITION safety timer setting value;
- The value can be: 40, 60, 80, 0; If 0, it means to disable this timer;
- default: 40.
- - active-semi,total-timeout: unit: hours;
- Specifies the charger's total safety timer setting value;
- The value can be: 3, 4, 5, 0; If 0, it means to disable this timer;
- default: 3.
-
-Example:
- pmic@5b {
- compatible = "active-semi,act8945a";
- reg = <0x5b>;
-
- charger {
- compatible = "active-semi,act8945a-charger";
- pinctrl-names = "default";
- pinctrl-0 = <&pinctrl_charger_chglev &pinctrl_charger_lbo &pinctrl_charger_irq>;
- interrupt-parent = <&pioA>;
- interrupts = <45 IRQ_TYPE_LEVEL_LOW>;
-
- active-semi,chglev-gpios = <&pioA 12 GPIO_ACTIVE_HIGH>;
- active-semi,lbo-gpios = <&pioA 72 GPIO_ACTIVE_LOW>;
- active-semi,input-voltage-threshold-microvolt = <6600>;
- active-semi,precondition-timeout = <40>;
- active-semi,total-timeout = <3>;
- };
- };
diff --git a/Documentation/devicetree/bindings/power/supply/active-semi,act8945a-charger.yaml b/Documentation/devicetree/bindings/power/supply/active-semi,act8945a-charger.yaml
new file mode 100644
index 000000000000..3f74bc19415d
--- /dev/null
+++ b/Documentation/devicetree/bindings/power/supply/active-semi,act8945a-charger.yaml
@@ -0,0 +1,76 @@
+# SPDX-License-Identifier: GPL-2.0
+%YAML 1.2
+---
+$id: "http://devicetree.org/schemas/power/supply/active-semi,act8945a-charger.yaml#";
+$schema: "http://devicetree.org/meta-schemas/core.yaml#";
+
+title: Active-semi ACT8945A Charger Function
+
+maintainers:
+ - Sebastian Reichel <sre@xxxxxxxxxx>
+
+allOf:
+ - $ref: power-supply.yaml#
+
+properties:
+ compatible:
+ const: active-semi,act8945a-charger
+
+ interrupts:
+ maxItems: 1
+
+ active-semi,chglev-gpios:
+ maxItems: 1
+ description: charge current level GPIO
+
+ active-semi,lbo-gpios:
+ maxItems: 1
+ description: low battery voltage detect GPIO
+
+ active-semi,input-voltage-threshold-microvolt:
+ description: |
+ Specifies the charger's input over-voltage threshold value.
+ Despite the name, specified values are in millivolt (mV).
+ Defaults to 6.6 V
+ enum: [ 6600, 7000, 7500, 8000 ]
+
+ active-semi,precondition-timeout:
+ $ref: /schemas/types.yaml#/definitions/uint32
+ description: |
+ Specifies the charger's PRECONDITION safety timer setting value in minutes.
+ If 0, it means to disable this timer.
+ Defaults to 40 minutes.
+ enum: [ 0, 40, 60, 80 ]
+
+ active-semi,total-timeout:
+ $ref: /schemas/types.yaml#/definitions/uint32
+ description: |
+ Specifies the charger's total safety timer setting value in hours;
+ If 0, it means to disable this timer;
+ Defaults to 3 hours.
+ enum: [ 0, 3, 4, 5 ]
+
+required:
+ - compatible
+ - interrupts
+ - active-semi,chglev-gpios
+ - active-semi,lbo-gpios
+
+additionalProperties: false
+
+examples:
+ - |
+ #include <dt-bindings/gpio/gpio.h>
+ #include <dt-bindings/interrupt-controller/irq.h>
+ pmic {
+ charger {
+ compatible = "active-semi,act8945a-charger";
+ interrupt-parent = <&pioA>;
+ interrupts = <45 IRQ_TYPE_LEVEL_LOW>;
+ active-semi,chglev-gpios = <&pioA 12 GPIO_ACTIVE_HIGH>;
+ active-semi,lbo-gpios = <&pioA 72 GPIO_ACTIVE_LOW>;
+ active-semi,input-voltage-threshold-microvolt = <6600>;
+ active-semi,precondition-timeout = <40>;
+ active-semi,total-timeout = <3>;
+ };
+ };
--
2.30.2