[PATCH 15/16] pcmcia: synclink_cs: drop redundant tty-port initialisation

From: Johan Hovold
Date: Wed Apr 07 2021 - 06:24:39 EST


The port close_delay and closing_wait parameters have already been by
tty_port_init() so drop the redundant driver initialisation to the
default values.

Signed-off-by: Johan Hovold <johan@xxxxxxxxxx>
---
drivers/char/pcmcia/synclink_cs.c | 2 --
1 file changed, 2 deletions(-)

diff --git a/drivers/char/pcmcia/synclink_cs.c b/drivers/char/pcmcia/synclink_cs.c
index 2be8d9a8eec5..3287a7627ed0 100644
--- a/drivers/char/pcmcia/synclink_cs.c
+++ b/drivers/char/pcmcia/synclink_cs.c
@@ -530,8 +530,6 @@ static int mgslpc_probe(struct pcmcia_device *link)
info->port.ops = &mgslpc_port_ops;
INIT_WORK(&info->task, bh_handler);
info->max_frame_size = 4096;
- info->port.close_delay = 5*HZ/10;
- info->port.closing_wait = 30*HZ;
init_waitqueue_head(&info->status_event_wait_q);
init_waitqueue_head(&info->event_wait_q);
spin_lock_init(&info->lock);
--
2.26.3