Re: [PATCH v2 1/1] serial: max310x: Use clock-names property matching to recognize EXTCLK

From: andriy.shevchenko@xxxxxxxxxxxxxxx
Date: Wed Jul 28 2021 - 11:19:26 EST


On Wed, Jul 28, 2021 at 02:52:17PM +0000, Dennis Giaya wrote:
> > v2: added Tested-by tag (Dennis), inverted comparison to leave
> > original flow
>
> I've tested v2 with the inverted comparison and it works under the same
> test conditions as v1.

Thanks! It's pending for v5.15-rc1.

--
With Best Regards,
Andy Shevchenko