[PATCH v6 33/48] mfd: ti_am335x_tscadc: Fix an error message

From: Miquel Raynal
Date: Fri Oct 15 2021 - 04:17:20 EST


The error message if we cannot retrieve the clock tells us that the
touchscreen controller clock was unavailable. This is wrong, this is the
"main" clock for the hardware block, it is not specific to the
touchscreen and won't change when we will introduce ADC1/magnetic reader
support so let's correct this comment.

Signed-off-by: Miquel Raynal <miquel.raynal@xxxxxxxxxxx>
Reviewed-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx>
---
drivers/mfd/ti_am335x_tscadc.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/mfd/ti_am335x_tscadc.c b/drivers/mfd/ti_am335x_tscadc.c
index bbf3fe46d3f4..5aa2905b5b9a 100644
--- a/drivers/mfd/ti_am335x_tscadc.c
+++ b/drivers/mfd/ti_am335x_tscadc.c
@@ -209,7 +209,7 @@ static int ti_tscadc_probe(struct platform_device *pdev)
*/
clk = devm_clk_get(&pdev->dev, NULL);
if (IS_ERR(clk)) {
- dev_err(&pdev->dev, "failed to get TSC fck\n");
+ dev_err(&pdev->dev, "failed to get fck\n");
err = PTR_ERR(clk);
goto err_disable_clk;
}
--
2.27.0