[PATCH v6 37/48] mfd: ti_am335x_tscadc: Support the correctly spelled DT property

From: Miquel Raynal
Date: Fri Oct 15 2021 - 04:17:33 EST


There was in the past a typo in the coordinate readouts property. The
bindings have been updated, the touchscreen driver as well and now
supports both. However, the MFD driver that is in charge of verifying
the validity of the property only checks the bogus one. Add support for
the correctly spelled DT property.

Fixes: c9aeb249bf72 ("Input: ti_am335x_tsc - fix spelling mistake in TSC/ADC DT binding")
Signed-off-by: Miquel Raynal <miquel.raynal@xxxxxxxxxxx>
Reviewed-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx>
---
drivers/mfd/ti_am335x_tscadc.c | 8 +++++++-
1 file changed, 7 insertions(+), 1 deletion(-)

diff --git a/drivers/mfd/ti_am335x_tscadc.c b/drivers/mfd/ti_am335x_tscadc.c
index 7b6d18144e27..07825cfd8aa8 100644
--- a/drivers/mfd/ti_am335x_tscadc.c
+++ b/drivers/mfd/ti_am335x_tscadc.c
@@ -144,8 +144,14 @@ static int ti_tscadc_probe(struct platform_device *pdev)
if (ti_adc_with_touchscreen(tscadc)) {
node = of_get_child_by_name(pdev->dev.of_node, "tsc");
of_property_read_u32(node, "ti,wires", &tscmag_wires);
- of_property_read_u32(node, "ti,coordiante-readouts", &readouts);
+ err = of_property_read_u32(node, "ti,coordinate-readouts",
+ &readouts);
+ if (err < 0)
+ of_property_read_u32(node, "ti,coordiante-readouts",
+ &readouts);
+
of_node_put(node);
+
if (tscmag_wires)
use_tsc = true;
} else {
--
2.27.0