Re: [PATCH] hwmon: Add driver for Gigabyte AORUS Waterforce AIO coolers

From: Guenter Roeck
Date: Sat Dec 02 2023 - 10:42:33 EST


On 12/2/23 07:01, Aleksa Savic wrote:
On 2023-10-20 15:02:08 GMT+02:00, Aleksa Savic wrote:
This driver exposes hardware sensors of the Gigabyte AORUS Waterforce
all-in-one CPU liquid coolers, which communicate through a proprietary
USB HID protocol. Report offsets were initially discovered in [1] and
confirmed by me on a Waterforce X240 by observing the sent reports from
the official software.

Available sensors are pump and fan speed in RPM, as well as coolant
temperature. Also available through debugfs is the firmware version.

Attaching a fan is optional and allows it to be controlled from the
device. If it's not connected, the fan-related sensors will report
zeroes.

The addressable RGB LEDs and LCD screen are not supported in this
driver and should be controlled through userspace tools.

[1]: https://github.com/liquidctl/liquidctl/issues/167

Signed-off-by: Aleksa Savic <savicaleksa83@xxxxxxxxx>
---
Documentation/hwmon/gigabyte_waterforce.rst | 47 +++
MAINTAINERS | 7 +
drivers/hwmon/Kconfig | 10 +
drivers/hwmon/Makefile | 1 +
drivers/hwmon/gigabyte_waterforce.c | 439 ++++++++++++++++++++
5 files changed, 504 insertions(+)
create mode 100644 Documentation/hwmon/gigabyte_waterforce.rst
create mode 100644 drivers/hwmon/gigabyte_waterforce.c

Hi Guenter,

Any thoughts on the patch? I'll fix the issues kernel bot reported
in v2.


I was waiting for that. In general, I am too busy to review patches if
0-day reports a problem, and wait for those to be resolved.

Guenter