Re: [PATCH net-next v4 04/12] net: ethernet: oa_tc6: implement software reset

From: Parthiban.Veerasooran
Date: Fri Apr 26 2024 - 02:38:58 EST


Hi Andrew,

On 24/04/24 4:56 am, Andrew Lunn wrote:
> EXTERNAL EMAIL: Do not click links or open attachments unless you know the content is safe
>
>> +static int oa_tc6_read_status0(struct oa_tc6 *tc6)
>> +{
>> + u32 regval;
>> + int ret;
>> +
>> + ret = oa_tc6_read_register(tc6, OA_TC6_REG_STATUS0, &regval);
>> + if (ret)
>> + return 0;
>
> If there is an error, your throw the error code away?
>
> It is a bit messy, since you are using this inside
> readx_poll_timeout(). I would probably do a netdev_warn() or similar,
> since it should not happen, and then return 0? I _think_ this is
> probably the first bus transaction we do, so if it fails, knowing the
> error code will help figuring out what is wrong with the SPI bus
> configuration.
OK, I will add the below print before "return 0;" in the next version.

dev_err(&tc6->spi->dev, "STATUS0 register read failed: %d\n", ret);

Best regards,
Parthiban V
>
> Andrew
>