Re: [PATCH 1/2] iio: humditiy: hdc3020: fix units for temperature and humidity measurement

From: Andy Shevchenko
Date: Thu Aug 21 2025 - 11:56:43 EST


On Thu, Aug 21, 2025 at 06:44:25PM +0300, Andy Shevchenko wrote:
> On Thu, Aug 21, 2025 at 05:23:54PM +0200, Dimitri Fedrau via B4 Relay wrote:

...

> > if (chan->type == IIO_TEMP)
> > - *val = 175;
> > + *val = 175000;
> > else
> > - *val = 100;
> > + *val = 100000;

> Perhaps use " * MILL" uin both cases?

Perhaps use " * MILLI" in both cases?

--
With Best Regards,
Andy Shevchenko