Re: [PATCH] iio: dac: ad3552r: use field_get() for power-down bit read

From: Nuno Sá

Date: Sat Apr 11 2026 - 09:49:27 EST


On Sat, 2026-04-11 at 10:46 +0530, Piyush Patle wrote:
> Use field_get() for the per-channel DAC power-down bit instead of an
> open-coded mask-and-shift sequence.
>
> No functional change.
>
> Signed-off-by: Piyush Patle <piyushpatle228@xxxxxxxxx>
> ---

Reviewed-by: Nuno Sá <nuno.sa@xxxxxxxxxx>

>  drivers/iio/dac/ad3552r.c | 3 +--
>  1 file changed, 1 insertion(+), 2 deletions(-)
>
> diff --git a/drivers/iio/dac/ad3552r.c b/drivers/iio/dac/ad3552r.c
> index 93c33bc3e1be..f206bba3a701 100644
> --- a/drivers/iio/dac/ad3552r.c
> +++ b/drivers/iio/dac/ad3552r.c
> @@ -167,8 +167,7 @@ static int ad3552r_read_raw(struct iio_dev *indio_dev,
>   mutex_unlock(&dac->lock);
>   if (err < 0)
>   return err;
> - *val = !((tmp_val & AD3552R_MASK_CH_DAC_POWERDOWN(ch)) >>
> -   __ffs(AD3552R_MASK_CH_DAC_POWERDOWN(ch)));
> + *val = !field_get(AD3552R_MASK_CH_DAC_POWERDOWN(ch), tmp_val);
>   return IIO_VAL_INT;
>   case IIO_CHAN_INFO_SCALE:
>   *val = dac->ch_data[ch].scale_int;