[PATCH v3 2/3] dt-bindings: iio: flow: add Sensirion SLF3S liquid flow sensor

From: Wadim Mueller

Date: Sat May 30 2026 - 16:56:29 EST


Document the bindings for the Sensirion SLF3S family of digital
liquid-flow sensors on I2C. The family currently covers the
SLF3S-0600F, SLF3S-1300F and SLF3S-4000B variants.

The driver auto-detects the variant from the product-information
register at probe time; the per-variant compatible strings exist
for documentation and dt_binding_check purposes.

The active calibration medium (water / IPA) is runtime-switchable
via the in_volumeflow_medium sysfs attribute and therefore not a
DT property.

Signed-off-by: Wadim Mueller <wafgo01@xxxxxxxxx>
---
.../bindings/iio/flow/sensirion,slf3s.yaml | 49 +++++++++++++++++++
MAINTAINERS | 8 +++
2 files changed, 57 insertions(+)
create mode 100644 Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml

diff --git a/Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml b/Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml
new file mode 100644
index 000000000..dc41120e0
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml
@@ -0,0 +1,49 @@
+# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/iio/flow/sensirion,slf3s.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Sensirion SLF3S liquid flow sensor
+
+maintainers:
+ - Wadim Mueller <wafgo01@xxxxxxxxx>
+
+description:
+ Family of digital liquid-flow sensors from Sensirion with I2C
+ interface. All family members share the same register map; sub-types
+ differ only in the flow scale factor and the calibrated measurement
+ range, both of which are detected at probe time via the
+ product-information register.
+
+properties:
+ compatible:
+ enum:
+ - sensirion,slf3s-0600f
+ - sensirion,slf3s-1300f
+ - sensirion,slf3s-4000b
+
+ reg:
+ maxItems: 1
+
+ vdd-supply: true
+
+required:
+ - compatible
+ - reg
+ - vdd-supply
+
+additionalProperties: false
+
+examples:
+ - |
+ i2c {
+ #address-cells = <1>;
+ #size-cells = <0>;
+
+ flow-sensor@8 {
+ compatible = "sensirion,slf3s-0600f";
+ reg = <0x08>;
+ vdd-supply = <&reg_3v3>;
+ };
+ };
diff --git a/MAINTAINERS b/MAINTAINERS
index 06a8c7457..222a03b6d 100644
--- a/MAINTAINERS
+++ b/MAINTAINERS
@@ -24187,6 +24187,14 @@ S: Maintained
F: Documentation/ABI/testing/sysfs-bus-iio-chemical-sgp40
F: drivers/iio/chemical/sgp40.c

+SENSIRION SLF3S LIQUID FLOW SENSOR DRIVER
+M: Wadim Mueller <wafgo01@xxxxxxxxx>
+R: Maxwell Doose <m32285159@xxxxxxxxx>
+L: linux-iio@xxxxxxxxxxxxxxx
+S: Maintained
+F: Documentation/devicetree/bindings/iio/flow/sensirion,slf3s.yaml
+F: drivers/iio/flow/slf3s.c
+
SENSIRION SPS30 AIR POLLUTION SENSOR DRIVER
M: Tomasz Duszynski <tduszyns@xxxxxxxxx>
S: Maintained
--
2.52.0