Re: [RFC PATCH] ASoC: rt700-sdw: always drain jack work on remove
From: Mark Brown
Date: Fri Jun 19 2026 - 07:48:36 EST
On Fri, Jun 19, 2026 at 04:03:34PM +0800, Runyu Xiao wrote:
> rt700_sdw_remove() drains jack_detect_work and jack_btn_check_work only
> when rt700->hw_init is true. That state bit is cleared by
> rt700_update_status() when the SoundWire slave becomes UNATTACHED, but a
> jack work item can already have been queued by rt700_interrupt_callback()
> or rt700_jack_init() while the device was initialized.
This doesn't apply against current code, please check and resend.
Attachment:
signature.asc
Description: PGP signature