Re: [PATCH v4 3/4] regulator: qcom-rpmh: readback voltage/bypass/mode/status set during bootup

From: Mark Brown

Date: Wed Jul 01 2026 - 08:13:35 EST


On Wed, Jul 01, 2026 at 03:36:47AM +0530, Kamal Wadhwa wrote:

> It seems that regulator registration failures happen after adding the read
> support ONLY if both of the conditions below are true for any regulator.

> 1. The [min or max]-microvolts values defined in the device tree didn’t
> exactly match with any of the selector voltages supported by the
> regulator.
> 2. On top of this, if the initial value read is out-of-range of the
> DT min,max limit.

That should just work, if there's some problem with that fix the core.

Attachment: signature.asc