Re: [PATCH 1/2] hwmon: (cgbc-hwmon): Fix current sensors ID lookup

From: Thomas Richard

Date: Fri Sep 11 2026 - 13:43:46 EST


On 9/11/26 3:57 PM, Guenter Roeck wrote:
> On 9/11/26 00:23, Thomas Richard wrote:
>> On 9/11/26 2:58 AM, Guenter Roeck wrote:
>>> On Thu, Sep 10, 2026 at 03:28:21PM +0200, Thomas Richard (congatec
>>> GmbH) wrote:
>>>> Current sensors on the Congatec Board Controller don't use
>>>> consecutive IDs,
>>>> unlike other sensor types (voltage, temperature, fan). The driver
>>>> assumed
>>>> consecutive IDs and performed a simple lookup, which caused an unknown
>>>> sensor warning. Define current sensor IDs explicitly.
>>>>
>>>> Changes the warning on conga-SA7 (type and channel are correct now).
>>>> Before:
>>>>    Board Controller returned an unknown sensor (type=2, channel=17),
>>>> ignore it
>>>> After:
>>>>    Board Controller returned an unknown sensor (bc_type=1,
>>>> bc_id=11), ignore it
>>>>
>>>> Cc: stable@xxxxxxxxxx
>>>> Fixes: 08ebc9def79f ("hwmon: Add Congatec Board Controller
>>>> monitoring driver")
>>>> Signed-off-by: Thomas Richard (congatec GmbH)
>>>> <thomas.richard@xxxxxxxxxxx>
>>>
>>> Applied.
>>>
>>
>> You pointed me that Sashiko reported a missing cgbc_hwmon_info array but
>> you applied the patch. Should I send a v2 or an other patch to fix it?
>>
> Sorry, too much going on. Either way is fine.
No problem, I sent a v2.

Best Regards,
Thomas