Re: [PATCH v2] dt-bindings: power: supply: battery: allow 101 ocv-capacity points
From: Conor Dooley
Date: Thu Sep 24 2026 - 13:57:01 EST
On Wed, Sep 23, 2026 at 10:15:35PM -0500, Ryan Brue wrote:
> ocv-capacity-table-N is capped at 100 points, while the capacity percent
> in each point may be anything from 0 to 100. A table with a point for
> every percent, both ends included, needs 101 and does not fit. Raise the
> cap to 101.
>
> power_supply_get_battery_info() sizes each table from the property, so
> no kernel change is needed.
>
> Assisted-by: LLM
Crazy what people seem to need LLMs to help with.
Acked-by: Conor Dooley <conor.dooley@xxxxxxxxxxxxx>
pw-bot: not-applicable
> Signed-off-by: Ryan Brue <ryanbrue.dev@xxxxxxxxx>
> ---
> As discussed with Henrik on v1: rather than a larger cap for one vendor's
> tables, which fit in 100 points once resampled, allow the one extra point
> that a table at every percent from 0 to 100 needs, and say so in the
> binding.
> ---
> Changes in v2:
> - Raise the cap to 101 instead of 128, with a comment saying why (Henrik)
> - Drop the justification from the vendor's tables; the figures in v1
> were for a different cell, and resampled tables fit in 100 points
> - Rebase on v7.3-rc4
> - Link to v1: https://patch.msgid.link/20260918-rbrue-suez-upstreaming-battery-ocv-table-128-v1-1-f477ef39ef0d@xxxxxxxxx
> ---
> Documentation/devicetree/bindings/power/supply/battery.yaml | 3 ++-
> 1 file changed, 2 insertions(+), 1 deletion(-)
>
> diff --git a/Documentation/devicetree/bindings/power/supply/battery.yaml b/Documentation/devicetree/bindings/power/supply/battery.yaml
> index 8ebf05d9497c..9575ee1491bb 100644
> --- a/Documentation/devicetree/bindings/power/supply/battery.yaml
> +++ b/Documentation/devicetree/bindings/power/supply/battery.yaml
> @@ -154,7 +154,8 @@ patternProperties:
> of the battery and corresponding battery capacity percent, which is used
> to look up battery capacity according to current OCV value. And the open
> circuit voltage unit is microvolt.
> - maxItems: 100
> + # One point for each capacity percent from 0 to 100
> + maxItems: 101
> items:
> items:
> - description: open circuit voltage (OCV) in microvolts
>
> ---
> base-commit: 93f51579e7df248780214094418f205253383cc5
> change-id: 20260917-rbrue-suez-upstreaming-battery-ocv-table-128-9ba83f9313bb
>
> Best regards,
> --
> Ryan Brue <ryanbrue.dev@xxxxxxxxx>
>
Attachment:
signature.asc
Description: PGP signature