Re: [PATCH 1/3] platform/x86: uniwill-laptop: Add PCSpecialist Recoil 16 AMD
From: Am Dev
Date: Fri Sep 25 2026 - 20:24:48 EST
On Sat, 26 Sept 2026 at 00:44, Armin Wolf <W_Armin@xxxxxx> wrote:
>
> it is to be expected that the EC firmware will emulate a full charge to 100 percent even
> when battery health conservation is enabled. I strongly warn you against enabling the
> charge limit on machines other that Intel NUC-based models because apparently Uniwill
> considers the charge limit feature as a preview on all other models, so accessing it
> might permanently damage you battery!
>
> I suggest you continue to use the battery charge modes.
>
Hi Armin,
thanks for the warning, I did not know that the charge limit is only a
preview feature on these models. I have stopped using it and will switch
to the battery charge modes in v2.
One question: the EC originally had 0 in EC_ADDR_CHARGE_CTRL, and it is
now 100 after I lifted the limit through charge_control_end_threshold.
Is 100 safe to leave, or should it be restored to 0?
Thanks,
Mohamed