[PATCH v1 0/1] power: supply: generic-adc-battery: Fix temperature IIO channel conversion
From: Svyatoslav Ryhel
Date: Sat Sep 26 2026 - 10:30:36 EST
Temperature IIO channel data is provided in milli-degrees, while
POWER_SUPPLY_PROP_TEMP is expected to be in deci-degrees. Adjust the
existing logic to reflect this conversion properly.
Svyatoslav Ryhel (1):
power: supply: generic-adc-battery: Fix temperature IIO channel
conversion
drivers/power/supply/generic-adc-battery.c | 9 +++++++--
1 file changed, 7 insertions(+), 2 deletions(-)
--